Recent advances in parallel imaging for MRI
J Hamilton, D Franson, N Seiberlich - Progress in nuclear magnetic …, 2017 - Elsevier
Abstract Magnetic Resonance Imaging (MRI) is an essential technology in modern
medicine. However, one of its main drawbacks is the long scan time needed to localize the …
medicine. However, one of its main drawbacks is the long scan time needed to localize the …
Acquisition strategies for spatially resolved magnetic resonance detection of hyperpolarized nuclei
GJ Topping, C Hundshammer, L Nagel… - … Resonance Materials in …, 2020 - Springer
Hyperpolarization is an emerging method in magnetic resonance imaging that allows
nuclear spin polarization of gases or liquids to be temporarily enhanced by up to five or six …
nuclear spin polarization of gases or liquids to be temporarily enhanced by up to five or six …
Lung morphometry using hyperpolarized 129Xe multi‐b diffusion MRI with compressed sensing in healthy subjects and patients with COPD
H Zhang, J Xie, S Xiao, X Zhao, M Zhang, L Shi… - Medical …, 2018 - Wiley Online Library
Purpose To demonstrate the feasibility of compressed sensing (CS) to accelerate the
acquisition of hyperpolarized (HP) 129Xe multi‐b diffusion MRI for quantitative assessments …
acquisition of hyperpolarized (HP) 129Xe multi‐b diffusion MRI for quantitative assessments …
Assessment of pulmonary morphometry using hyperpolarized 129Xe diffusion‐weighted MRI with variable‐sampling‐ratio compressed sensing patterns
Q Zhou, H Li, Q Rao, M Zhang, X Zhao, L Shen… - Medical …, 2023 - Wiley Online Library
Abstract Background Hyperpolarized (HP) 129Xe multiple b‐values diffusion‐weighted
magnetic resonance imaging (DW‐MRI) has been widely used for quantifying pulmonary …
magnetic resonance imaging (DW‐MRI) has been widely used for quantifying pulmonary …
Hyperpolarized 129Xe MRI at low field: Current status and future directions
S Perron, A Ouriadov - Journal of Magnetic Resonance, 2023 - Elsevier
Abstract Magnetic Resonance Imaging (MRI) is dictated by the magnetization of the sample,
and is thus a low-sensitivity imaging method. Inhalation of hyperpolarized (HP) noble gases …
and is thus a low-sensitivity imaging method. Inhalation of hyperpolarized (HP) noble gases …
Compounding morphometric parameters for prioritization of vulnerable watersheds for land restoration planning in Beas sub basin, India using geospatial techniques
S Nehra, K Sur, VK Verma… - Water Practice & …, 2024 - iwaponline.com
The Beas sub basin falling under the Indus basin in Northern India is experiencing notable
changes due to human interventions since the rise of civilization in the Indus valley. The …
changes due to human interventions since the rise of civilization in the Indus valley. The …
Rapid single‐breath hyperpolarized noble gas MRI‐based biomarkers of airspace enlargement
Background Multi‐b diffusion‐weighted hyperpolarized‐gas MRI measures pulmonary
airspace‐enlargement using apparent diffusion coefficients (ADCs) and mean‐linear …
airspace‐enlargement using apparent diffusion coefficients (ADCs) and mean‐linear …
Detection of the mild emphysema by quantification of lung respiratory airways with hyperpolarized xenon diffusion MRI
W Ruan, J Zhong, K Wang, G Wu, Y Han… - Journal of Magnetic …, 2017 - Wiley Online Library
Purpose To demonstrate the feasibility to quantify the lung respiratory airway in vivo with
hyperpolarized xenon diffusion magnetic resonance imaging (MRI), which is able to detect …
hyperpolarized xenon diffusion magnetic resonance imaging (MRI), which is able to detect …
Diffusion lung imaging with hyperpolarized gas MRI
DA Yablonskiy, AL Sukstanskii, JD Quirk - NMR in Biomedicine, 2017 - Wiley Online Library
Lung imaging using conventional 1H MRI presents great challenges because of the low
density of lung tissue, lung motion and very fast lung tissue transverse relaxation (typical T2 …
density of lung tissue, lung motion and very fast lung tissue transverse relaxation (typical T2 …
Incorporation of prior knowledge of signal behavior into the reconstruction to accelerate the acquisition of diffusion MRI data
JFPJ Abascal, M Desco… - IEEE transactions on …, 2017 - ieeexplore.ieee.org
Diffusion MRI data are generally acquired using hyperpolarized gases during patient breath-
hold, which yields a compromise between achievable image resolution, lung coverage, and …
hold, which yields a compromise between achievable image resolution, lung coverage, and …