Role of contact force sensing in catheter ablation of cardiac arrhythmias: evolution or history repeating itself?

N Ariyarathna, S Kumar, SP Thomas… - Clinical …, 2018 - jacc.org
Adequate catheter-tissue contact facilitates efficient heat energy transfer to target tissue.
Tissue contact is thus critical to achieving lesion transmurality and success of …

2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement …

S Tzeis, EP Gerstenfeld, J Kalman, EB Saad… - Europace, 2024 - academic.oup.com
In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based
safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007 …

A multifunctional soft robot for cardiac interventions

J Rogatinsky, D Recco, J Feichtmeier, Y Kang… - Science …, 2023 - science.org
In minimally invasive endovascular procedures, surgeons rely on catheters with low
dexterity and high aspect ratios to reach an anatomical target. However, the environment …

Randomized trial comparing pulmonary vein isolation using the SmartTouch catheter with or without real-time contact force data

W Ullah, A McLean, MH Tayebjee, D Gupta, MR Ginks… - Heart rhythm, 2016 - Elsevier
Background Contact force (CF) information may improve the safety and efficacy of ablation
for paroxysmal atrial fibrillation (PAF). Objective The purpose of this study was to assess the …

High-frequency low-tidal volume ventilation improves long-term outcomes in AF ablation: a multicenter prospective study

J Osorio, PC Zei, JC Díaz, AL Varley, GX Morales… - Clinical …, 2023 - jacc.org
Background High-frequency, low-tidal-volume (HFLTV) ventilation is a safe and simple
strategy to improve catheter stability and first-pass isolation during pulmonary vein (PV) …

Efforts to enhance catheter stability improve atrial fibrillation ablation outcome

MD Hutchinson, FC Garcia, JE Mandel, N Elkassabany… - Heart Rhythm, 2013 - Elsevier
BACKGROUND: Contemporary techniques to enhance anatomical detail and catheter
contact during atrial fibrillation (AF) ablation include (1) the integration of preacquired …

Ablation index and surround flow catheter irrigation: impedance-based appraisal in clinical ablation

W Ullah, RJ Hunter, MC Finlay, A McLean… - JACC: Clinical …, 2017 - jacc.org
Objectives: This study sought to assess the impact of ablation power and catheter irrigation
during clinical radiofrequency ablation using impedance drop. Background: In preclinical …

Optimal lesion size index to prevent conduction gap during pulmonary vein isolation

N Kanamori, T Kato, S Sakagami… - Journal of …, 2018 - Wiley Online Library
Introduction A novel real‐time lesion size index (LSI) that incorporates contact force (CF),
time, and power has been developed for safe and effective catheter ablation. The optimal …

Rapid pacing and high‐frequency jet ventilation additively improve catheter stability during atrial fibrillation ablation

A Aizer, JK Qiu, AV Cheng, PB Wu… - Journal of …, 2020 - Wiley Online Library
Introduction Catheter stability during atrial fibrillation ablation is associated with higher
ablation success rates. Rapid cardiac pacing and high‐frequency jet ventilation (HFJV) …

[HTML][HTML] Computational ECG mapping and respiratory gating to optimize stereotactic ablative radiotherapy workflow for refractory ventricular tachycardia

G Ho, TF Atwood, AR Bruggeman, KL Moore… - Heart rhythm O2, 2021 - Elsevier
Background Stereotactic ablative radiotherapy (SAbR) is an emerging therapy for refractory
ventricular tachycardia (VT). However, the current workflow is complicated, and the precision …