Transformer model for inrush current calculations: Simulations, measurements and sensitivity analysis

N Chiesa, BA Mork, HK Høidalen - IEEE Transactions on Power …, 2010 - ieeexplore.ieee.org
The modeling of inrush currents that occur upon energization of a transformer is a challenge
for Electromagnetic Transients Programs due to limitations in available transformer models …

Power transformer modeling for inrush current calculation

N Chiesa - 2010 - ntnuopen.ntnu.no
In this thesis a general purpose transformer model for low and medium frequency transient
studies is developed and verified. The inrush current phenomena during no-load …

Topology-correct reversible transformer model

SE Zirka, YI Moroz, CM Arturi, N Chiesa… - … on Power Delivery, 2012 - ieeexplore.ieee.org
A topology-correct transformer model, which covers core operation under heavy saturation
conditions, is presented. A method of accounting for magnetic fluxes outside the core and …

Estimation method of voltage sag frequency considering transformer energization

Y Wang, S Li, XY Xiao - IEEE Transactions on Power Delivery, 2020 - ieeexplore.ieee.org
The inrush current generated by power transformer energization (TE) causes voltage sag of
the nearby bus, the typical residual voltage of the voltage sag caused by transformer …

Novel approach for reducing transformer inrush currents: Laboratory measurements, analytical interpretation and simulation studies

N Chiesa, HK Høidalen - IEEE Transactions on Power Delivery, 2010 - ieeexplore.ieee.org
Transformer inrush currents can lead to a reduction of transformer lifetime and inadvertent
tripping of relays. This paper investigates a novel approach for minimizing the inrush current …

A novel strategy for reducing inrush current of three-phase transformer considering residual flux

S Fang, H Ni, H Lin, SL Ho - IEEE Transactions on Industrial …, 2016 - ieeexplore.ieee.org
Proper use of phase-controlled switching technology by controlling the making or breaking
of the circuit breaker (CB) at predetermined phase angles of current or voltage can improve …

[PDF][PDF] 电力变压器铁心剩磁的测量与削弱方法

戈文祺, 汪友华, 陈学广, 肖树欣, 杨晓光… - 电工技术 …, 2015 - dgjsxb.ces-transaction.com
摘要大型电力变压器在各种检测以及运行之后, 由于其铁心结构的封闭性以及铁磁材料固有的磁
滞现象, 会在铁心中留有剩磁. 剩磁的存在将加速电力变压器铁心的磁化饱和, 产生励磁涌流 …

Residual flux in the closed magnetic core of a power transformer

W Ge, Y Wang, Z Zhao, X Yang… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
When a transformer is de-energized, the magnetic core material will contain a certain
amount of residual magnetic flux. This flux may intensify saturation and lead to high transient …

Transformer inrush currents

RA Turner, KS Smith - IEEE Industry Applications Magazine, 2010 - ieeexplore.ieee.org
This article presents the harmonic analysis of transformer inrush currents in offshore power
systems. Offshore production facilities interconnected by subsea cables are becoming …

Static and dynamic hysteresis models for studying transformer transients

SE Zirka, YI Moroz, AJ Moses… - IEEE Transactions on …, 2011 - ieeexplore.ieee.org
Shortcomings of the classical approach in describing magnetization processes in grain-
oriented transformer steel is analyzed. A noniterative method of accounting for hysteresis …