State‐of‐the‐art on the protection of FACTS compensated high‐voltage transmission lines: a review

S Biswas, PK Nayak - High voltage, 2018 - Wiley Online Library
In recent years, the inclusion of flexible AC transmission systems (FACTS)‐based
compensating devices such as a thyristor‐controlled series capacitor (TCSC) and a unified …

Towards automated statistical partial discharge source classification using pattern recognition techniques

H Janani, B Kordi - High Voltage, 2018 - Wiley Online Library
This study presents a comprehensive review of the automated classification in partial
discharge (PD) source identification and probabilistic interpretation of the classification …

[PDF][PDF] Optimal overcurrent relays coordination in the presence multi tcsc on power systems using BBO algorithm

M Zellagui, R Benabid, M Boudour… - … Intelligent Systems and …, 2015 - mecs-press.org
Optimal coordination of Inverse Definite Minimum Time (IDMT) direction overcurrent relays
in the power systems in the presence of multiple Thyristor Controller Series Capacitor …

Impact of apparent reactance injected by TCSR on distance relay in presence phase to earth fault

M Zellagui, A Chaghi - Advances in Electrical and Electronic …, 2013 - advances.utc.sk
This research paper presents the impact study of apparent reactance injected by series
Flexible AC Transmission System (FACTS) ie Thyristor Controlled Series Reactor (TCSR) on …

[PDF][PDF] A comparative study of impact series FACTS devices on distance relay setting in 400 kV Transmission Line

M Zellagui, A Chaghi - Journal of Electrical and Electronics …, 2012 - researchgate.net
This research paper presents a comparative study of the performance of distance protection
for transmission line 400 kV in Algerian transmission networks at Group Sonelgaz (Algerian …

Suggestion of a new protection scheme for a transmission system equipped with a thyristor-controlled series capacitor

MC Dinh, MQ Tran, JI Lee, SJ Lee, CH Lee, J Yoon… - Energies, 2019 - mdpi.com
A thyristor-controlled series capacitor (TCSC) is employed to a transmission line in order to
enhance the usable capacity of the present as well as upgraded lines, improve system …

[PDF][PDF] Impact of TCSC on distance protection setting based modified particle swarm optimization techniques

M Zellagui, A Chaghi - International Journal of Intelligent Systems …, 2013 - researchgate.net
This paper presents the application of the Modified Particle Swarm Optimization (MPSO)
technique for optimal settings zones for MHO distance relay protect 400 kV single …

[PDF][PDF] Impact of Distributed Generation and Series FACTS Compensator on Directional Over-current Protection Coordination

L Bougouffa, A Chaghi - International Journal of Hybrid …, 2014 - researchgate.net
Protection system is used to protect components against fault as fast as possible and also to
minimize the area around it from fault. Nowadays because of the existence of Distributed …

Investigation of TCSC controller effect on IDMT directional over-current relay

L Bougouffa, A Chaghi - Procedia-Social and Behavioral Sciences, 2015 - Elsevier
With the presence of FACTS controllers in power system transmission for enhancing the
power system controllability and stability, the problem of coordinating protective relays …

[PDF][PDF] Modeling the effects of PWMSC and fault resistance on ground fault system in MV distribution line

M Zellagui, HA Hassan - WSEAS Trans. Syst. Control, 2017 - wseas.com
A newly developed AC link converter based series compensation is a recent series Flexible
Alternating Current Transmission System (FACTS) controller. The Pulse Width Modulated …