Evaluating cell metabolism through autofluorescence imaging of NAD (P) H and FAD
OI Kolenc, KP Quinn - Antioxidants & redox signaling, 2019 - liebertpub.com
Significance: Optical imaging using the endogenous fluorescence of metabolic cofactors has
enabled nondestructive examination of dynamic changes in cell and tissue function both in …
enabled nondestructive examination of dynamic changes in cell and tissue function both in …
Interplay between optical vortices and condensed matter
Interest in the multiple facets of optical vortices has flourished in the last three decades. This
review examines the basic research and applications of the interplay between optical …
review examines the basic research and applications of the interplay between optical …
Fast fit-free analysis of fluorescence lifetime imaging via deep learning
Fluorescence lifetime imaging (FLI) provides unique quantitative information in biomedical
and molecular biology studies but relies on complex data-fitting techniques to derive the …
and molecular biology studies but relies on complex data-fitting techniques to derive the …
[HTML][HTML] FLIM as a promising tool for cancer diagnosis and treatment monitoring
Fluorescence lifetime imaging microscopy (FLIM) has been rapidly developed over the past
30 years and widely applied in biomedical engineering. Recent progress in fluorophore …
30 years and widely applied in biomedical engineering. Recent progress in fluorophore …
A high dynamic range 128× 120 3-D stacked CMOS SPAD image sensor SoC for fluorescence microendoscopy
AT Erdogan, T Al Abbas, N Finlayson… - IEEE Journal of Solid …, 2022 - ieeexplore.ieee.org
A miniaturized 1.4 mm mm, single-photon avalanche diode (SPAD) image sensor with a five-
wire interface is designed for time-resolved fluorescence microendoscopy. This is the first …
wire interface is designed for time-resolved fluorescence microendoscopy. This is the first …
In vitro and in vivo NIR fluorescence lifetime imaging with a time-gated SPAD camera
Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast
mechanism to monitor biological parameters and molecular events in vivo. Single-photon …
mechanism to monitor biological parameters and molecular events in vivo. Single-photon …
[HTML][HTML] Fluorescence guided surgery
HL Stewart, DJS Birch - Methods and Applications in …, 2021 - iopscience.iop.org
Fluorescence guided surgery (FGS) is an imaging technique that allows the surgeon to
visualise different structures and types of tissue during a surgical procedure that may not be …
visualise different structures and types of tissue during a surgical procedure that may not be …
Deep learning in biomedical optics
This article reviews deep learning applications in biomedical optics with a particular
emphasis on image formation. The review is organized by imaging domains within …
emphasis on image formation. The review is organized by imaging domains within …
[HTML][HTML] Fluorescence lifetime imaging with a megapixel SPAD camera and neural network lifetime estimation
Fluorescence lifetime imaging microscopy (FLIM) is a key technology that provides direct
insight into cell metabolism, cell dynamics and protein activity. However, determining the …
insight into cell metabolism, cell dynamics and protein activity. However, determining the …
Novel automated non invasive detection of ocular surface squamous neoplasia using multispectral autofluorescence imaging
A Habibalahi, C Bala, A Allende, AG Anwer… - The ocular surface, 2019 - Elsevier
Abstract Purpose Diagnosing Ocular surface squamous neoplasia (OSSN) using newly
designed multispectral imaging technique. Methods Eighteen patients with histopathological …
designed multispectral imaging technique. Methods Eighteen patients with histopathological …