[HTML][HTML] Optimal pmu placement technique to maximize measurement redundancy based on closed neighbourhood search
LR Hyacinth, V Gomathi - Energies, 2021 - mdpi.com
This paper proposes a method for the optimal placement of phasor measurement units
(PMUs) for the complete observability of a power system based on the degree of the …
(PMUs) for the complete observability of a power system based on the degree of the …
Intelligent prediction of out‐of‐step condition on synchronous generators because of transient instability crisis
H Zare, Y Alinejad‐Beromi… - … Transactions on Electrical …, 2019 - Wiley Online Library
This paper presents an adaptive scheme for predicting out‐of‐step (OOS) condition of
synchronous generator based on the Bayesian technique. The proposed scheme performs …
synchronous generator based on the Bayesian technique. The proposed scheme performs …
A multi-objective placement of phasor measurement units using fuzzified artificial bee colony algorithm, considering system observability and voltage stability
K Arul Jeyaraj, V Rajasekaran… - … of Experimental & …, 2016 - Taylor & Francis
This paper presents Multi-objective Optimal Placement of Phasor measurement units
(MOPP) to improve the performance of power system monitoring and control. It is proposed …
(MOPP) to improve the performance of power system monitoring and control. It is proposed …
A multi-objective placement of phasor measurement units considering observability and measurement redundancy using firefly algorithm
V Rajasekaran, K Chandrasekaran - Journal of Electrical …, 2015 - koreascience.kr
This paper proposes a multi-objective optimal placement method of Phasor Measurement
Units (PMUs) in large electric transmission systems. It is proposed for minimizing the number …
Units (PMUs) in large electric transmission systems. It is proposed for minimizing the number …
A multi-objective PMU placement method considering observability and measurement redundancy using ABC algorithm
A Kulanthaisamy, R Vairamani… - Advances in Electrical …, 2014 - go.gale.com
This paper presents a Multi-objective Optimal Placement of Phasor Measurement Units
(MOPP) method in large electric transmission systems. It is proposed for minimizing the …
(MOPP) method in large electric transmission systems. It is proposed for minimizing the …
A new algorithm for predicting out‐of‐step condition in large‐scale power systems using rotor speed–acceleration
AR Sobbouhi… - … Transactions on Electrical …, 2016 - Wiley Online Library
Transient instability is one of the major threats to system security which can cause out‐of‐
step condition. Out‐of‐step condition can cause mechanical and thermal damages to …
step condition. Out‐of‐step condition can cause mechanical and thermal damages to …
Optimal placing of PMUs in a constrained grid: an approach
J BHONsLE, A Junghare - Turkish journal of Electrical …, 2016 - journals.tubitak.gov.tr
Synchronized phasor measurement units (PMUs) are replacing conventional measuring
meters in modern power networks. The paradigm of grid monitoring has shifted to a wider …
meters in modern power networks. The paradigm of grid monitoring has shifted to a wider …
Optimal phasor measuring unit placement by binary particle swarm optimization
S Kumari, P Walde, A Iqbal… - 2017 8th International …, 2017 - ieeexplore.ieee.org
This work presents a technique for the optimal Phasor Measurement Units (PMUs)
placement for complete power network observability with number of PMUs as minimum as …
placement for complete power network observability with number of PMUs as minimum as …
Monitoring of Electric Distribution Grids: Existing, Priority, and Objective
M Nayel, M Morad, W Mohamed - 2019 IEEE Sustainable …, 2019 - ieeexplore.ieee.org
The smart distribution grids monitoring process refers to consistently collect data related to
all distributed resources conditions. The dynamic nature of distribution grid systems makes …
all distributed resources conditions. The dynamic nature of distribution grid systems makes …
Optimal PMU placement to achieve complete observability of Idaho Power Co. System
O Ciniglio, M Papic, M Vaiman… - 2017 IEEE Power & …, 2017 - ieeexplore.ieee.org
This paper presents an effective practical approach for identifying optimal locations of
Phasor Measurement Units (PMUs) to achieve complete system observability. The …
Phasor Measurement Units (PMUs) to achieve complete system observability. The …