Multi-physical coupling field study of 500 kV GIL: Simulation, characteristics, and analysis

H Niu, Z Chen, H Zhang, X Luo, X Zhuang, X Li… - IEEE …, 2020 - ieeexplore.ieee.org
With the construction of a large number of hydropower stations, transmission lines crossing
a river and urban utility tunnels, gas insulated transmission line (GIL) has been applied …

An approach to thermal modeling of power cables installed in ducts

G Petrović, M Cvetković, T Garma, T Kilić - Electric power systems research, 2023 - Elsevier
The power cables laying in the urban areas require utilization of the protective ducts, mainly
to facilitate the faulty section replacement. However, the use of cable ducts results in …

Study on temperature rise characteristics of GIS disconnector under different operating conditions

L Zhao, Z Wang, H Zhu, G Hong, J Ren… - … on Power Delivery, 2020 - ieeexplore.ieee.org
The degradation of the electrical contact in a gas insulated switchgear (GIS) is closely
related to overheating at the contact. However, the disconnector contact is one of the hot …

Heat Transfer Analysis of Different Conditions for SF/N Gas-Insulated Transmission Lines

YJ Qiao, R Liang, P Gao, SY Zhu… - … on Power Delivery, 2020 - ieeexplore.ieee.org
Considering that SF 6 is a potent greenhouse gas, SF 6/N 2 gas mixtures are preferred to
serve as the insulating gas for its environmental friendliness and good insulation. Since heat …

Countermeasures of abnormal heating of cable grounding line near three-phase reactor

Y Zhang, Z Zhao, X Xiao, H Sun, Z Chen… - Electric Power Systems …, 2023 - Elsevier
Cable termination near to three-phase dry-type air-core reactor (DAR) is prone to abnormal
heating. In response to this problem, this paper firstly establishes the finite element model of …

[HTML][HTML] A novel method for fast computation of the temperature rise and optimal design of GIL based on thermal network model

S Cheng, Y Zhao, K Xie, B Hu, J Zhang, X Yang - Energy, 2024 - Elsevier
Accurate and fast computation of the temperature rise of gas-insulated transmission lines
(GIL) is of great significance to its efficient operation and optimal design. This study …

[HTML][HTML] Thermal model of DC conductors for railway traction networks: A hosting capacity assessment

MG Mahairi, B Mohamed, P Arboleya - Electric Power Systems Research, 2024 - Elsevier
In this paper, the authors have adapted existing thermal models for the calculation of
conductor temperature for use in electrical distribution systems for railway applications in …

Fast calculation of electromagnetic-thermal-fulid multiphysics coupling of GIL based on hybrid model

X Yang, Y Zhao, S Cheng - Electric Power Systems Research, 2025 - Elsevier
To ensure the reliability and stability of gas-insulated transmission lines (GIL) operation, it is
crucial to accurately calculate the temperature distribution. This paper proposes a fast …

Gas-insulated transmission lines state classification and fault chamber location based on the divergence characteristics of temperature parameters

R Liang, YJ Qiao, SY Zhu, P Gao, XZ Tang… - Electric Power Systems …, 2022 - Elsevier
SuTong GIL (Gas-insulated transmission lines) is a critical connection for the UHV AC loop
network in East China, therefore, its state classification and fault chamber location are …

Numerical study on thermal-electrical-mechanical coupling mechanism of electrical connectors considering contact resistance

W He, Y Feng, S Wu, W Wang - Proceedings of the …, 2024 - journals.sagepub.com
Electrical connectors are widely used in electromechanical equipment. Their rough surfaces
inevitably induce electrical contact resistance (ECR) and thermal contact resistance (TCR) …