Multi-physical coupling field study of 500 kV GIL: Simulation, characteristics, and analysis
H Niu, Z Chen, H Zhang, X Luo, X Zhuang, X Li… - IEEE …, 2020 - ieeexplore.ieee.org
With the construction of a large number of hydropower stations, transmission lines crossing
a river and urban utility tunnels, gas insulated transmission line (GIL) has been applied …
a river and urban utility tunnels, gas insulated transmission line (GIL) has been applied …
An approach to thermal modeling of power cables installed in ducts
The power cables laying in the urban areas require utilization of the protective ducts, mainly
to facilitate the faulty section replacement. However, the use of cable ducts results in …
to facilitate the faulty section replacement. However, the use of cable ducts results in …
Study on temperature rise characteristics of GIS disconnector under different operating conditions
L Zhao, Z Wang, H Zhu, G Hong, J Ren… - … on Power Delivery, 2020 - ieeexplore.ieee.org
The degradation of the electrical contact in a gas insulated switchgear (GIS) is closely
related to overheating at the contact. However, the disconnector contact is one of the hot …
related to overheating at the contact. However, the disconnector contact is one of the hot …
Heat Transfer Analysis of Different Conditions for SF/N Gas-Insulated Transmission Lines
YJ Qiao, R Liang, P Gao, SY Zhu… - … on Power Delivery, 2020 - ieeexplore.ieee.org
Considering that SF 6 is a potent greenhouse gas, SF 6/N 2 gas mixtures are preferred to
serve as the insulating gas for its environmental friendliness and good insulation. Since heat …
serve as the insulating gas for its environmental friendliness and good insulation. Since heat …
Countermeasures of abnormal heating of cable grounding line near three-phase reactor
Y Zhang, Z Zhao, X Xiao, H Sun, Z Chen… - Electric Power Systems …, 2023 - Elsevier
Cable termination near to three-phase dry-type air-core reactor (DAR) is prone to abnormal
heating. In response to this problem, this paper firstly establishes the finite element model of …
heating. In response to this problem, this paper firstly establishes the finite element model of …
[HTML][HTML] A novel method for fast computation of the temperature rise and optimal design of GIL based on thermal network model
S Cheng, Y Zhao, K Xie, B Hu, J Zhang, X Yang - Energy, 2024 - Elsevier
Accurate and fast computation of the temperature rise of gas-insulated transmission lines
(GIL) is of great significance to its efficient operation and optimal design. This study …
(GIL) is of great significance to its efficient operation and optimal design. This study …
[HTML][HTML] Thermal model of DC conductors for railway traction networks: A hosting capacity assessment
In this paper, the authors have adapted existing thermal models for the calculation of
conductor temperature for use in electrical distribution systems for railway applications in …
conductor temperature for use in electrical distribution systems for railway applications in …
Fast calculation of electromagnetic-thermal-fulid multiphysics coupling of GIL based on hybrid model
X Yang, Y Zhao, S Cheng - Electric Power Systems Research, 2025 - Elsevier
To ensure the reliability and stability of gas-insulated transmission lines (GIL) operation, it is
crucial to accurately calculate the temperature distribution. This paper proposes a fast …
crucial to accurately calculate the temperature distribution. This paper proposes a fast …
Gas-insulated transmission lines state classification and fault chamber location based on the divergence characteristics of temperature parameters
R Liang, YJ Qiao, SY Zhu, P Gao, XZ Tang… - Electric Power Systems …, 2022 - Elsevier
SuTong GIL (Gas-insulated transmission lines) is a critical connection for the UHV AC loop
network in East China, therefore, its state classification and fault chamber location are …
network in East China, therefore, its state classification and fault chamber location are …
Numerical study on thermal-electrical-mechanical coupling mechanism of electrical connectors considering contact resistance
W He, Y Feng, S Wu, W Wang - Proceedings of the …, 2024 - journals.sagepub.com
Electrical connectors are widely used in electromechanical equipment. Their rough surfaces
inevitably induce electrical contact resistance (ECR) and thermal contact resistance (TCR) …
inevitably induce electrical contact resistance (ECR) and thermal contact resistance (TCR) …