[图书][B] Springer handbook of experimental fluid mechanics
This Handbook consolidates authoritative and state-of-the-art information from the large
number of disciplines used in Experimental Fluid Mechanics into a readable desk reference …
number of disciplines used in Experimental Fluid Mechanics into a readable desk reference …
Real-time unsteady loads measurements using hot-film sensors
A Mangalam, T Moes - 22nd Applied Aerodynamics Conference and …, 2004 - arc.aiaa.org
In the past several decades, the flight envelope has been expanding for military aircraft into
high angles of attack and increased angular rates. Entry into increased angle-of-attack (α) …
high angles of attack and increased angular rates. Entry into increased angle-of-attack (α) …
A detailed procedure for measuring turbulent velocity fluctuations using constant-voltage anemometry
A Mohammed-Taifour, J Weiss, A Sadeghi, J Vétel… - Experiments in …, 2015 - Springer
A detailed procedure to use a constant-voltage anemometer (CVA) for the accurate
measurement of turbulent flows is proposed. The procedure is based on the usual small …
measurement of turbulent flows is proposed. The procedure is based on the usual small …
Sensitivity evaluation of thermoresistive sensor constant temperature anemometers
SYC Catunda, MV Gabriel, FR Sousa… - Proceedings of the …, 2004 - ieeexplore.ieee.org
Constant temperature anemometers (CTA) have been extensively studied in the literature,
normally using NTC or PTC thermoresistive sensors. A comparative analysis of the …
normally using NTC or PTC thermoresistive sensors. A comparative analysis of the …
Laserstrukturierte Planarsensoren zur Bestimmung respiratorischer Parameter
DH Dill - 2016 - mediatum.ub.tum.de
Diese Arbeit behandelt die Entwicklung von Planarsensoren zur Messung von
Luftströmungen, insbesondere für medizinische Applikationen. Die Spirometrie stellt hier die …
Luftströmungen, insbesondere für medizinische Applikationen. Die Spirometrie stellt hier die …
Calibration Methods for a Constant Voltage Anemometer-Operated Hot-Wire in a Hypersonic Flow
CA Reimann - 2003 - repository.lib.ncsu.edu
The calibration of measurements made with a CVA-operated hot-wire, in a quiet hypersonic
wind tunnel, are examined. Two calibration methods are evaluated. The first calibration …
wind tunnel, are examined. Two calibration methods are evaluated. The first calibration …
[引用][C] Phenomena-based real-time aerodynamic measurement system (PRAMS)
SM Mangalam - 2003 IEEE Aerospace Conference …, 2003 - ieeexplore.ieee.org
The one hundred years following the first successful flight by Wright Brothers have been a
time of tremendous progress in all areas of aerospace engineering. In some respects it may …
time of tremendous progress in all areas of aerospace engineering. In some respects it may …