Microwave SINIS Detectors

M Tarasov, A Gunbina, A Chekushkin, R Yusupov… - Applied Sciences, 2022 - mdpi.com
Featured Application Among cryogenic microwave detectors and bolometers, the SINIS
detectors are promising candidates for practical applications due to their wide dynamic …

Carbon nanotube bolometers

M Tarasov, J Svensson, L Kuzmin… - Applied Physics …, 2007 - pubs.aip.org
A cryogenic bolometer has been fabricated using a bundle of single-walled carbon
nanotubes as absorber. A bolometric response was observed when the device was exposed …

Fast terahertz continuous-wave detector based on weakly ionized plasma

L Hou, W Shi - IEEE electron device letters, 2012 - ieeexplore.ieee.org
A fast terahertz (THz) continuous-wave detector based on weakly ionized plasma is
developed. Its response time can be less than a microsecond according to calculation. By …

Bridging the terahertz gap for chaotic sources with superconducting junctions

DR Gulevich, VP Koshelets, FV Kusmartsev - Physical Review B, 2019 - APS
We observe a broadband chaotic signal of terahertz frequency emitted from a
superconducting junction. The generated radiation has a wide spectrum reaching 0.7 THz …

Terahertz radiation detection using glow discharge detectors by electrical and optical modes

L Hou, C Chai, Z Wang, L Yang, J Wang… - … on Electron Devices, 2021 - ieeexplore.ieee.org
Based on the phenomenon that the incident terahertz (THz) radiation can increase the
discharge current and luminescent intensity of a glow discharge detector (GDD), the …

Investigation of various operation modes of a miniature superconducting detector of microwave radiation

IA Devyatov, PA Krutitskiĭ, MY Kupriyanov - JETP letters, 2006 - Springer
Nonequilibrium electron and phonon distribution functions have been calculated for a
metallic absorber of a promising miniature superconducting detector irradiated by …

Investigation of a nonequilibrium electron subsystem in low-temperature microwave detectors

IA Devyatov, MY Kupriyanov - Journal of Experimental and Theoretical …, 2004 - Springer
The electron energy distributions arising in small-size metal absorbers of microwave
radiation detectors operating at ultralow temperatures have been calculated using the …

Fast broadband inexpensive weakly ionised plasma detector used in terahertz continuous-wave imaging

L Hou, W Shi - Electronics letters, 2012 - IET
A continuous-wave terahertz (THz) detector based on weakly ionised plasma in a
discharged neon lamp has been developed. The inexpensive detector has a wide spectral …

Superconducting terahertz receivers for space-borne and balloon-borne radio telescopes

VP Koshelets, MA Tarasov - Bulletin of the Russian Academy of Sciences …, 2016 - Springer
A superconducting heterodyne receiver based on superconductor–insulator–
superconductor (SIS) junctions and a bolometric receiver based on superconductor …

Изготовление и исследование структур нормальный металл-изолятор-сверхпроводник Al/AlO/Nb

МА Маркина, АМ Чекушкин, МА Тарасов… - Журнал технической …, 2024 - mathnet.ru
Представлены разработка, изготовление и исследование структур на основе
туннельных переходов нормальный металл-изолятор-сверхпроводник. Произведен …