[PDF][PDF] 含风电继电保护应用中的电流互感器饱和电流重构方法
黄梓欣, 林湘宁, 马啸, 吴宇奇, 魏繁荣 - 电工技术学报, 2022 - dgjsxb.ces-transaction.com
摘要传统继电保护研究往往将抗电流互感器(CT) 饱和视作离线判据整定的必要条件, 实际上,
利用在线快速重构所得电流数据参与保护计算是一种新思路. 但在风电接入系统后, 流经CT …
利用在线快速重构所得电流数据参与保护计算是一种新思路. 但在风电接入系统后, 流经CT …
Deep learning approach for single-phase ground fault section location via feature fusion in resonant distribution networks
JH Gao, MF Guo, S Lin, DY Chen, H Bai - Expert Systems with Applications, 2025 - Elsevier
Identifying fault sections in single-phase ground (SPG) faults is essential for electric utilities
to promptly isolate faults and restore service. A deep learning-based approach leveraging …
to promptly isolate faults and restore service. A deep learning-based approach leveraging …
Coordination of protective relays in distribution systems considering uncertainty caused by renewables and demands based on orthogonal experiments
YY Hong, CW Yu, YD Lee, JL Jiang… - Sustainable Energy, Grids …, 2023 - Elsevier
The operations of distribution systems are more challenging than in past decades because
of the penetration of distributed generation (DG). Several serious problems may be caused …
of the penetration of distributed generation (DG). Several serious problems may be caused …
[HTML][HTML] A novel protection relay for neutral effectively grounded distribution networks independent on sequence components
X Zeng, X Tong, N Tong - International Journal of Electrical Power & Energy …, 2024 - Elsevier
The neutral effectively grounded system (NEGS), increasingly adopted in medium-voltage
urban AC distribution networks, exhibits heightened susceptibility to fault-induced …
urban AC distribution networks, exhibits heightened susceptibility to fault-induced …
Information Fusion Approach for Transformer Protection: Concept, Application, and Field Data Verification
SA Ahmadi, M Sanaye-Pasand… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
The ultimate goal of power transformer protection system is to quickly and reliably detect
internal faults while remaining stable for external faults and transients. Since in the …
internal faults while remaining stable for external faults and transients. Since in the …
FPGA-Based Smart Sensor to Detect Current Transformer Saturation during Inrush Current Measurement
GJ Martínez-Figueroa, F Córcoles-López, S Bogarra - Sensors, 2023 - mdpi.com
Current transformer saturation affects measurement accuracy and, consequently, protection
reliability. One important concern in the case of overcurrent protections is the discrimination …
reliability. One important concern in the case of overcurrent protections is the discrimination …
A novel measurement‐protection‐integrated current transformer based on hybrid core and magnetic field sensor
Z Zhang, B Chen, C Tian, Y Chen… - IET Electric Power …, 2024 - Wiley Online Library
Current transformers (CTs) are widely used for energy metering, relay protection, condition
monitoring and control circuits. However, CT saturation may lead to non‐negligible …
monitoring and control circuits. However, CT saturation may lead to non‐negligible …
A Novel Transient Saturation Detection Method for P-class Current Transformer Using Improved Hausdorff Distance Algorithm
J Duan, M Zhao, Y Lei, X Guan - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
The P-class current transformer (CT) widely used at present creates the problem that
transient saturation occurs and leads to the reduction of the reliability of the differential …
transient saturation occurs and leads to the reduction of the reliability of the differential …
Design of Heart-shaped Current Sensor Based on Incomplete Magnetic Cancellation
W Li, X Tang, Y Lu, L Yan, Y Wu… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
High current measurement technology is of great importance in many fields, including power
system protection and control, power metering, and power consumption reduction …
system protection and control, power metering, and power consumption reduction …
A Data-Aided Power Transformer Differential Protection Without Inrush Blocking Module
When a slightly faulty transformer closes without load, the current waveform presents the
coexistence of inrush and fault current. At this time, the inrush blocking module will block the …
coexistence of inrush and fault current. At this time, the inrush blocking module will block the …