Survey of recent progress on lightning and lightning protection research
Lightning and lightning induced effects have significant influence on many aspects affecting
the public, which makes the research of lightning and lightning protection very important …
the public, which makes the research of lightning and lightning protection very important …
Transient electromagnetic interferences between a power line and a pipeline due to a lightning discharge: An EMTP-based approach
AG Martins-Britto, CM Moraes, FV Lopes - Electric Power Systems …, 2021 - Elsevier
This paper presents a transient electromagnetic interference study in a right-of-way shared
between an 88 kV transmission line and a 14''pipeline, with a complex approximation layout …
between an 88 kV transmission line and a 14''pipeline, with a complex approximation layout …
Total AC interferences between a power line subject to a single-phase fault and a nearby pipeline with multilayered soil
CM Moraes, GH de Sá Matos… - IEEE Transactions …, 2023 - ieeexplore.ieee.org
This article describes the problem of electromagnetic interferences between power lines and
metallic structures, caused by inductive and conductive coupling mechanisms, and the main …
metallic structures, caused by inductive and conductive coupling mechanisms, and the main …
Towards automated statistical partial discharge source classification using pattern recognition techniques
H Janani, B Kordi - High Voltage, 2018 - Wiley Online Library
This study presents a comprehensive review of the automated classification in partial
discharge (PD) source identification and probabilistic interpretation of the classification …
discharge (PD) source identification and probabilistic interpretation of the classification …
Analysis of induced voltage on pipeline located close to parallel distribution system
Gas and oil pipelines are widely used to supply customers. They are often laid in parallel
with high voltage power lines, sharing right of way. When the pipeline is located near …
with high voltage power lines, sharing right of way. When the pipeline is located near …
Inductive interferences between a 500 kV power line and a pipeline with a complex approximation layout and multilayered soil
AG Martins-Britto, CM Moraes, FV Lopes - Electric Power Systems …, 2021 - Elsevier
This paper presents a steady-state electromagnetic interference study between a 500 kV
overhead transmission line and a neighboring pipeline, based on data from a real project …
overhead transmission line and a neighboring pipeline, based on data from a real project …
Study of transmission line AC interference with steel-buried pipelines under lightning strikes
X Wang, Y Wang, T Sun, X Yang, L Yang… - Electric Power Systems …, 2023 - Elsevier
When lightning strikes the transmission line tower, the lightning current flows into the soil
along the tower grounding device, causing serious AC interference with nearby steel-buried …
along the tower grounding device, causing serious AC interference with nearby steel-buried …
Study on electromagnetic influence of 750kV AC transmission lines on multiple buried pipelines
S Haifeng, W Pei, C Haojing… - 2016 Asia-Pacific …, 2016 - ieeexplore.ieee.org
Due to the electric power industry and oil and gas industry have a close principle to the
preferential transmission route. The electromagnetic impact of power transmission line is …
preferential transmission route. The electromagnetic impact of power transmission line is …
Моделирование электромагнитных влияний гибкого симметричного токопровода на протяженные металлические конструкции
АВ Крюков, АВ Черепанов, АЕ Крюков - … . Серия: Естественные и …, 2021 - elibrary.ru
В системах электроснабжения (СЭС) энергоемких промышленных предприятий
применяются многоамперные токопроводы с проводами больших сечений …
применяются многоамперные токопроводы с проводами больших сечений …