State‐of‐the‐art on the protection of FACTS compensated high‐voltage transmission lines: a review

S Biswas, PK Nayak - High voltage, 2018 - Wiley Online Library
In recent years, the inclusion of flexible AC transmission systems (FACTS)‐based
compensating devices such as a thyristor‐controlled series capacitor (TCSC) and a unified …

[图书][B] Fault location on power networks

MM Saha, JJ Izykowski, E Rosolowski - 2009 - books.google.com
Electric power systems will always be exposed to the failure of their components. When a
fault occurs on a line, it is crucial for the fault location to be identified as accurately as …

Fault classification and section identification of an advanced series-compensated transmission line using support vector machine

PK Dash, SR Samantaray… - IEEE transactions on …, 2006 - ieeexplore.ieee.org
Distance protection of flexible ac transmission lines, including the thyristor-controlled series
compensator (TCSC), static synchronous compensator, and static var compensator has …

Global power grid interconnection for sustainable growth: concept, project and research direction

SF Rafique, P Shen, Z Wang, R Rafique… - IET Generation …, 2018 - Wiley Online Library
Transcontinental grid interconnection and clean energy development for sustainability are
the prime objectives to address through global energy interconnection (GEI) platform. Key …

A fault detection and classification scheme for unified power flow controller compensated transmission lines connecting wind farms

S Biswas, PK Nayak - IEEE Systems Journal, 2020 - ieeexplore.ieee.org
In recent years, there is an increasing trend of integrating large capacity offshore wind farms
into power grids through UPFC compensated TLs for accommodating large flow of power …

Performance evaluation of a distance relay as applied to a transmission system with UPFC

X Zhou, H Wang, RK Aggarwal… - IEEE Transactions on …, 2006 - ieeexplore.ieee.org
This paper presents analytical and simulation results of the application of distance relays for
the protection of transmission systems employing flexible alternating current transmission …

Distance protection of AC grid with HVDC-connected offshore wind generators

L He, CC Liu, A Pitto, D Cirio - IEEE Transactions on Power …, 2013 - ieeexplore.ieee.org
When a transmission line close to points of common coupling (PCCs) experiences a short-
circuit (SC) fault, the fast reactive power control of voltage-source converter-HVDC (VSC …

Applying distance relay for voltage sag source detection

AK Pradhan, A Routray - IEEE Transactions on Power Delivery, 2005 - ieeexplore.ieee.org
This paper proposes the application of distance relay information for a voltage sag source
detection problem. It is found that the magnitude and angle of impedance before and after …

Impact of VSC-based multiline FACTS controllers on distance protection of transmission lines

M Khederzadeh, A Ghorbani - IEEE transactions on Power …, 2011 - ieeexplore.ieee.org
By utilizing multiline voltage-source (VSC)-based flexible ac transmission system (FACTS)
controllers, independent controllability over each compensated line of a multiline system can …

Impact of SVC on the protection of transmission lines

A Ghorbani, M Khederzadeh, B Mozafari - International Journal of Electrical …, 2012 - Elsevier
The impact of Static Var Compensator (SVC) on the apparent impedance seen by the
transmission line distance relay is investigated in this paper. Analytical results are presented …