Soft X-ray optimization studies on a dense plasma focus device operated in neon and argon in repetitive mode
This paper investigates the emission characteristics of a high-performance low-energy (3-kJ)
repetitive dense plasma focus device, NX2, operated at up to 1-Hz repetition rate to develop …
repetitive dense plasma focus device, NX2, operated at up to 1-Hz repetition rate to develop …
Research with plasma foci in countries of Asia, Africa, and Latin America
AE Dubinov, EI Fomicheva, LA Senilov - Reviews of Modern Plasma …, 2020 - Springer
This paper considers the modern level of technique, research, and application of “plasma
focus” facilities in the countries of Asia, Africa, and Latin America. A description of the …
focus” facilities in the countries of Asia, Africa, and Latin America. A description of the …
Formation of a sheared flow Z pinch
RP Golingo, U Shumlak, BA Nelson - Physics of Plasmas, 2005 - pubs.aip.org
The ZaP Flow Z-Pinch project is experimentally studying the effect of sheared flows on Z-
pinch stability. It has been shown theoretically that when d V z∕ dr exceeds 0.1 k VA the …
pinch stability. It has been shown theoretically that when d V z∕ dr exceeds 0.1 k VA the …
Analysis of the nitrogen ion beam generated in a low-energy plasma focus device by a Faraday cup operating in the secondary electron emission mode
H Kelly, A Lepone, A Marquez… - IEEE transactions on …, 1998 - ieeexplore.ieee.org
The energy distribution and flux of fast nitrogen particles generated in a Mather-type plasma
focus device operating at 0.4 Torr of N/sub 2/pressure is reported. A Faraday cup operating …
focus device operating at 0.4 Torr of N/sub 2/pressure is reported. A Faraday cup operating …
Comparative study of soft x-ray emission characteristics in a low energy dense plasma focus device
An investigation on the soft x rays emitted in a 2.2 kJ Mather-type dense plasma focus
device using a multichannel diode spectrometer and a simple pinhole camera is reported …
device using a multichannel diode spectrometer and a simple pinhole camera is reported …
Effect of insulator length and fill pressure on filamentation and neutron production in a 4.6 kJ dense plasma focus
Optimization of neutron yields from dense plasma focus devices is a complex multi-faceted
challenge that necessitates the prudent selection of mechanical constraints such as the …
challenge that necessitates the prudent selection of mechanical constraints such as the …
Low-energy plasma focus as a tailored X-ray source
Abstract A low-energy (2.3 kJ) plasma focus energized by a single 32-μF capacitor charged
at 12 kV with filling gases hydrogen, neon, and argon is investigated as an X-ray source …
at 12 kV with filling gases hydrogen, neon, and argon is investigated as an X-ray source …
Effect of anode designs on ion emission characteristics of a plasma focus device
A comparative study on the ion emission characteristics such as flux and energy, and their
variation in angular positions and operating gas pressures has been carried out in a …
variation in angular positions and operating gas pressures has been carried out in a …
Angular distribution of ion beams energy and flux in a plasma focus device operated with argon gas
M Etminan, FM Aghamir - Vacuum, 2021 - Elsevier
Energy and flux of ion beams in a Mather type (5 kJ) plasma focus device was investigated.
The experiments were performed with argon as the chamber gas at the optimum pressure of …
The experiments were performed with argon as the chamber gas at the optimum pressure of …
Anode length optimization in a modified plasma focus device for optimal x-ray yields
NK Neog, SR Mohanty, E Hotta - Journal of applied physics, 2006 - pubs.aip.org
The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-
filling modified plasma focus device has been investigated. The time-resolved investigation …
filling modified plasma focus device has been investigated. The time-resolved investigation …