Condition monitoring of industrial electric machines: State of the art and future challenges
SB Lee, GC Stone, J Antonino-Daviu… - IEEE Industrial …, 2020 - ieeexplore.ieee.org
The limitations of the thermal, vibration, or electrical monitoring of electric machines such as
false indications, low sensitivity, and difficulty of fault interpretation have recently been …
false indications, low sensitivity, and difficulty of fault interpretation have recently been …
Broken bar fault detection and diagnosis techniques for induction motors and drives: State of the art
MEED Atta, DK Ibrahim, MI Gilany - IEEE Access, 2022 - ieeexplore.ieee.org
Motors are the higher energy-conversion devices that consume around 40% of the global
electrical generated energy. Induction motors are the most popular motor type due to their …
electrical generated energy. Induction motors are the most popular motor type due to their …
A method for detecting half-broken rotor bar in lightly loaded induction motors using current
This paper presents an effective method of motor current signature analysis for detecting half-
as well as full broken single rotor bar fault of a squirrel-cage induction machine under …
as well as full broken single rotor bar fault of a squirrel-cage induction machine under …
Automatic classification of rotor faults in soft-started induction motors, based on persistence spectrum and convolutional neural network applied to stray-flux signals
V Biot-Monterde, A Navarro-Navarro… - Sensors, 2022 - mdpi.com
Due to their robustness, versatility and performance, induction motors (IMs) have been
widely used in many industrial applications. Despite their characteristics, these machines …
widely used in many industrial applications. Despite their characteristics, these machines …
Electrical monitoring under transient conditions: A new paradigm in electric motors predictive maintenance
J Antonino-Daviu - Applied Sciences, 2020 - mdpi.com
Featured Application Electric motors condition monitoring. Abstract Electric motors condition
monitoring is a field of paramount importance for industry. In recent decades, there has been …
monitoring is a field of paramount importance for industry. In recent decades, there has been …
Smart sensor for fault detection in induction motors based on the combined analysis of stray-flux and current signals: A flexible, robust approach
I Zamudio-Ramírez, RA Osornio-Rios… - IEEE Industry …, 2021 - ieeexplore.ieee.org
The most recent trend in the electric motor condition monitoring area relies on combining the
information obtained from different machine quantities to reach a more reliable conclusion …
information obtained from different machine quantities to reach a more reliable conclusion …
Advanced analysis of motor currents for the diagnosis of the rotor condition in electric motors operating in mining facilities
JA Antonino-Daviu, A Quijano-Lopez… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
Predictive maintenance of electric motors is a topic of increasing importance in many
industrial applications. The mining industry is not an exception; many electric motors …
industrial applications. The mining industry is not an exception; many electric motors …
Rotor unbalance and broken rotor bar detection in inverter-fed induction motors at start-up and steady-state regimes by high-resolution spectral analysis
RJ Romero-Troncoso, A Garcia-Perez… - Electric Power Systems …, 2016 - Elsevier
Fault detection in induction motors operated by inverters is an actual industrial need. Most
line-fed machines are being replaced by inverter-fed drives, due to their improved speed …
line-fed machines are being replaced by inverter-fed drives, due to their improved speed …
Fault detection of circulation pumps on the basis of motor current evaluation
V Becker, T Schwamm, S Urschel… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Motor current signature analysis (MCSA) for fault detection has found widespread
application, especially for induction motors. The basis of MCSA is the evaluation of a motor's …
application, especially for induction motors. The basis of MCSA is the evaluation of a motor's …
Reliable airgap search coil based detection of induction motor rotor faults under false negative motor current signature analysis indications
Rotor cage damage in induction motors must be detected and repaired to prevent costly in-
service failures that can occur due to broken cage fragments or arcing. Motor current …
service failures that can occur due to broken cage fragments or arcing. Motor current …