Bioelectrical impedance spectroscopy for monitoring mammalian cells and tissues under different frequency domains: A review
Bioelectrical impedance analysis and bioelectrical impedance spectroscopy (BIA/BIS) of
tissues reveal important information on molecular composition and physical structure that is …
tissues reveal important information on molecular composition and physical structure that is …
Application of process tomography to multiphase flow measurement in industrial and biomedical fields: A review
This paper reviews the latest development and emerging technologies on the application of
process tomography to multiphase flow measurement in industrial and biomedical fields. In …
process tomography to multiphase flow measurement in industrial and biomedical fields. In …
High-precision electrical impedance tomography data acquisition system for brain imaging
X Shi, W Li, F You, X Huo, C Xu, Z Ji, R Liu… - IEEE Sensors …, 2018 - ieeexplore.ieee.org
In electrical impedance tomography (EIT), it is difficult to obtain the intracranial impedance
due to the highly resistive skull enclosing the brain. Therefore, a high-precision data …
due to the highly resistive skull enclosing the brain. Therefore, a high-precision data …
[HTML][HTML] In situ crack mapping of large-scale self-sensing concrete pavements using electrical resistance tomography
This study aims to validate the large-scale application of self-sensing concrete in airport
runway pavements and to use electrical resistance tomography (ERT) for characterizing …
runway pavements and to use electrical resistance tomography (ERT) for characterizing …
Multi-frequency electrical impedance tomography (EIT) of the adult human head: initial findings in brain tumours, arteriovenous malformations and chronic stroke …
MFEIT (multi-frequency electrical impedance tomography) could distinguish between
ischaemic and haemorrhagic stroke and permit the urgent use of thrombolytic drugs in …
ischaemic and haemorrhagic stroke and permit the urgent use of thrombolytic drugs in …
A multi-frequency electrical impedance tomography system for real-time 2D and 3D imaging
This paper presents the design and evaluation of a configurable, fast multi-frequency
Electrical Impedance Tomography (mfEIT) system for real-time 2D and 3D imaging …
Electrical Impedance Tomography (mfEIT) system for real-time 2D and 3D imaging …
A review on electrical impedance tomography spectroscopy
J Padilha Leitzke, H Zangl - Sensors, 2020 - mdpi.com
Electrical Impedance Tomography Spectroscopy (EITS) enables the reconstruction of
material distributions inside an object based on the frequency-dependent characteristics of …
material distributions inside an object based on the frequency-dependent characteristics of …
Frequency-difference electrical impedance tomography (fdEIT): algorithm development and feasibility study
Frequency-difference electrical impedance tomography (fdEIT) has been proposed to deal
with technical difficulties of a conventional static EIT imaging method caused by unknown …
with technical difficulties of a conventional static EIT imaging method caused by unknown …
Design and calibration of a compact multi-frequency EIT system for acute stroke imaging
A McEwan, A Romsauerova, R Yerworth… - Physiological …, 2006 - iopscience.iop.org
A new, compact UCLH Mk 2.5 EIT system has been developed and calibrated for EIT
imaging of the head. Improvements include increased input and output impedances …
imaging of the head. Improvements include increased input and output impedances …
A wideband electrical impedance tomography system based on sensitive bioimpedance spectrum bandwidth
A wideband electrical impedance tomography (EIT) system based on bioimpedance
spectrum (BIS) analysis was proposed to image biological objects. The system integrated 16 …
spectrum (BIS) analysis was proposed to image biological objects. The system integrated 16 …