Bioelectrical impedance spectroscopy for monitoring mammalian cells and tissues under different frequency domains: A review

S Abasi, JR Aggas, GG Garayar-Leyva… - ACS measurement …, 2022 - ACS Publications
Bioelectrical impedance analysis and bioelectrical impedance spectroscopy (BIA/BIS) of
tissues reveal important information on molecular composition and physical structure that is …

Application of process tomography to multiphase flow measurement in industrial and biomedical fields: A review

J Yao, M Takei - IEEE Sensors Journal, 2017 - ieeexplore.ieee.org
This paper reviews the latest development and emerging technologies on the application of
process tomography to multiphase flow measurement in industrial and biomedical fields. In …

High-precision electrical impedance tomography data acquisition system for brain imaging

X Shi, W Li, F You, X Huo, C Xu, Z Ji, R Liu… - IEEE Sensors …, 2018 - ieeexplore.ieee.org
In electrical impedance tomography (EIT), it is difficult to obtain the intracranial impedance
due to the highly resistive skull enclosing the brain. Therefore, a high-precision data …

[HTML][HTML] In situ crack mapping of large-scale self-sensing concrete pavements using electrical resistance tomography

S Gupta, YA Lin, HJ Lee, J Buscheck, R Wu… - Cement and Concrete …, 2021 - Elsevier
This study aims to validate the large-scale application of self-sensing concrete in airport
runway pavements and to use electrical resistance tomography (ERT) for characterizing …

Multi-frequency electrical impedance tomography (EIT) of the adult human head: initial findings in brain tumours, arteriovenous malformations and chronic stroke …

A Romsauerova, A McEwan, L Horesh… - Physiological …, 2006 - iopscience.iop.org
MFEIT (multi-frequency electrical impedance tomography) could distinguish between
ischaemic and haemorrhagic stroke and permit the urgent use of thrombolytic drugs in …

A multi-frequency electrical impedance tomography system for real-time 2D and 3D imaging

Y Yang, J Jia - Review of Scientific Instruments, 2017 - pubs.aip.org
This paper presents the design and evaluation of a configurable, fast multi-frequency
Electrical Impedance Tomography (mfEIT) system for real-time 2D and 3D imaging …

A review on electrical impedance tomography spectroscopy

J Padilha Leitzke, H Zangl - Sensors, 2020 - mdpi.com
Electrical Impedance Tomography Spectroscopy (EITS) enables the reconstruction of
material distributions inside an object based on the frequency-dependent characteristics of …

Frequency-difference electrical impedance tomography (fdEIT): algorithm development and feasibility study

JK Seo, J Lee, SW Kim, H Zribi… - Physiological …, 2008 - iopscience.iop.org
Frequency-difference electrical impedance tomography (fdEIT) has been proposed to deal
with technical difficulties of a conventional static EIT imaging method caused by unknown …

Design and calibration of a compact multi-frequency EIT system for acute stroke imaging

A McEwan, A Romsauerova, R Yerworth… - Physiological …, 2006 - iopscience.iop.org
A new, compact UCLH Mk 2.5 EIT system has been developed and calibrated for EIT
imaging of the head. Improvements include increased input and output impedances …

A wideband electrical impedance tomography system based on sensitive bioimpedance spectrum bandwidth

C Tan, S Liu, J Jia, F Dong - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
A wideband electrical impedance tomography (EIT) system based on bioimpedance
spectrum (BIS) analysis was proposed to image biological objects. The system integrated 16 …