Mitigation of power quality issues due to high penetration of renewable energy sources in electric grid systems using three-phase APF/STATCOM technologies: A …

WUK Tareen, M Aamir, S Mekhilef, M Nakaoka… - Energies, 2018 - mdpi.com
This study summarizes an analytical review on the comparison of three-phase static
compensator (STATCOM) and active power filter (APF) inverter topologies and their control …

A dual-time transform assisted intelligent relaying scheme for the STATCOM-compensated transmission line connecting wind farm

S Biswas, PK Nayak, G Pradhan - IEEE Systems Journal, 2021 - ieeexplore.ieee.org
The fixed-impedance-based distance relaying schemes find limitation in providing reliable
protection to transmission lines connecting doubly fed induction generator based large …

Hilbert Huang transform based online differential relay algorithm for a shunt-compensated transmission line

S Biswal, M Biswal, OP Malik - IEEE Transactions on Power …, 2018 - ieeexplore.ieee.org
A differential protection scheme, based on real-time analysis of a time-frequency based
technique, is proposed for a transmission line with a midpoint-connected static synchronous …

Adaptive distance protection scheme for shunt‐FACTS compensated line connecting wind farm

R Dubey, SR Samantaray… - IET Generation …, 2016 - Wiley Online Library
To improve the performance of the conventional distance protection scheme for
compensated lines with high resistance faults, an adaptive distance protection scheme is …

Design and implementation of hybrid transmission line protection scheme using signal processing techniques

A Kumar, H Sharma, RN Mahia… - … on Electrical Energy …, 2022 - Wiley Online Library
A hybrid scheme for transmission line protection (HSTLP) using the Stockwell transform
(ST), Wigner distribution function (WDF), and alienation coefficient (ACF) is designed …

Digital impedance pilot relaying scheme for STATCOM compensated TL for fault phase classification with fault location

AR Singh, NR Patne, VS Kale… - IET Generation …, 2017 - Wiley Online Library
This study presents calculation of fundamental frequency‐based per phase digital
impedance pilot relaying (DIPR) scheme for static synchronous compensator (STATCOM) …

Smart branch and droop controller based power quality improvement in microgrids

P Ray, SR Salkuti - International Journal of Emerging Electric Power …, 2020 - degruyter.com
This paper presents two unique smart branch controller for compensating several power
quality disturbances. The first proposed intelligent branch controller comprises a series …

Synchronized measurement based an adaptive distance relaying scheme for STATCOM compensated transmission line

AR Singh, NR Patne, VS Kale - Measurement, 2018 - Elsevier
Protection of bulk power delivering transmission line (TL) is very important for power system
stability and reliability. The environmental and right of way restrictions delayed the …

ERF‐based fault detection scheme for STATCOM‐compensated line

OH Gupta, M Tripathy - International Transactions on Electrical …, 2017 - Wiley Online Library
The shunt flexible AC transmission system devices affect the protection schemes because of
reactive power injection. Therefore, robust protection schemes are required. This study …

Kullback‐Leibler divergence based differential protection scheme for shunt compensated transmission line

S Biswal, M Tajdinian, AR Adly… - IET Generation …, 2021 - Wiley Online Library
Conventional transmission line protection algorithms may experience delay or even mal‐
operation in presence of shunt compensation due to various non‐fault transient …