[HTML][HTML] Damage response of conventionally reinforced two-way spanning concrete slab under eccentric impacting drop weight loading
Reinforced concrete (RC) structures are generally designed to carry quasi-static gravity
loads through almost indispensable components namely slab, however, it may be subjected …
loads through almost indispensable components namely slab, however, it may be subjected …
Behavior of two-way RC slab with different reinforcement orientation layouts of tension steel under drop load impact
In this research work, dynamic nonlinear incremental finite element analysis is conducted in
ABAQUS software with an inbuilt explicit module to study the impact response of a two-way …
ABAQUS software with an inbuilt explicit module to study the impact response of a two-way …
Role of shear reinforcements on the punching shear resistance of two-way RC slab subjected to impact loading
The possibility of acting impulsive loads such as blast and impact on gravity load-carrying
structural members such as slabs during their construction and service life cannot be ruled …
structural members such as slabs during their construction and service life cannot be ruled …
Performance of (1) concrete-filled double-skin steel tube with and without core concrete, and (2) concrete-filled steel tubular axially loaded composite columns under …
Composite structural members such as concrete-filled double-skin steel tube (CFDSST) and
concrete-filled double steel tubular (CFDST) columns are increasingly being utilized in …
concrete-filled double steel tubular (CFDST) columns are increasingly being utilized in …
Close-range blast response prediction of hollow circular concrete columns with varied hollowness ratio, arrangement of compression steel, and confining stirrups' …
Blasts and accidental explosions are being reported more frequently than before with
grievous injuries and loss of lives and damage to the structure, increasing the concern of …
grievous injuries and loss of lives and damage to the structure, increasing the concern of …
Effect of concrete strength on the dynamic behavior of axially loaded reinforced concrete column subjected to close-range explosive loading
In a structural system, the load-bearing columns are one of the most important and
vulnerable structural members. The destruction of columns may lead to partial failure or …
vulnerable structural members. The destruction of columns may lead to partial failure or …
Ultra high performance concrete and C-FRP tension Re-bars: A unique combinations of materials for slabs subjected to low-velocity drop impact loading
In this research work, different combinations of normal strength concrete (NSC), ultra-high-
performance concrete (UHPC), and steel fiber-reinforced UHPC (SFR-UHPC) concrete with …
performance concrete (UHPC), and steel fiber-reinforced UHPC (SFR-UHPC) concrete with …
Reinforced cement concrete (RCC) shelter and prediction of its blast loads capacity
Reinforced concrete (RC) blast shelters are of momentous importance during warfare. On-
the-ground shelters are also used to store chemical explosives, ammunition, and artillery …
the-ground shelters are also used to store chemical explosives, ammunition, and artillery …
Blast resistance prediction of clay brick masonry wall strengthened with steel wire mesh, and C-FRP laminate under explosion loading: a finite element analysis
A detailed finite element micro-model of an Unreinforced Masonry (URM) wall of clay bricks,
1600 mm× 2100 mm× 240 mm, is made in ABAQUS/Explicit-v. 6.15 code and analysed …
1600 mm× 2100 mm× 240 mm, is made in ABAQUS/Explicit-v. 6.15 code and analysed …
Effect of blast location and explosive mass on the dynamic behavior of a bowstring steel highway girder bridge subjected to air-blast
Steel bridges are preferred for their lesser construction time and are used in territorial border
areas, to develop road connectivity between neighboring countries, and also in the existing …
areas, to develop road connectivity between neighboring countries, and also in the existing …