DC microgrids: a propitious smart grid paradigm for smart cities

SS Rangarajan, R Raman, A Singh, CK Shiva… - Smart Cities, 2023 - mdpi.com
Recent years have seen a surge in interest in DC microgrids as DC loads and DC sources
like solar photovoltaic systems, fuel cells, batteries, and other options have become more …

Protection techniques for DC microgrid-A review

A Chandra, GK Singh, V Pant - Electric Power Systems Research, 2020 - Elsevier
The proliferation of DC microgrid is a commendable stride for the future power system to
match the load requirement precisely with the distributed generation. The potential benefits …

A fault diagnosis and postfault reconfiguration scheme for interleaved boost converter in PV-based system

MW Ahmad, NBY Gorla, H Malik… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
To utilize the solar photovoltaic (PV) energy efficiently, dc-dc converters are widely used in
both grid-connected and stand-alone systems. Among the various topologies, interleaved dc …

An observer-based switch open-circuit fault diagnosis of DC–DC converter for fuel cell application

S Zhuo, A Gaillard, L Xu, C Liu… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
The power semiconductor device is one of the most fragile components of the dc-dc power
converters in industrial applications. In this article, a Luenberger observer-based switch fault …

Data mining applications to fault diagnosis in power electronic systems: A systematic review

A Moradzadeh, B Mohammadi-Ivatloo… - … on Power Electronics, 2021 - ieeexplore.ieee.org
Early fault detection in power electronic systems (PESs) to maintain reliability is one of the
most important issues that has been significantly addressed in recent years. In this article …

Open-circuit switch fault diagnosis and fault-tolerant control for output-series interleaved boost DC–DC converter

L Xu, R Ma, R Xie, J Xu, Y Huangfu… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
This article proposes a fault-tolerant control method for an input-parallel–output-series
(IPOS) converter under open-circuit switch failure, which mainly focuses on two parts: fault …

Multi open-/short-circuit fault-tolerance using modified SVM technique for three-level HANPC converters

LM Halabi, IM Alsofyani, KB Lee - IEEE Transactions on Power …, 2021 - ieeexplore.ieee.org
Open-and short-circuit faults are the most severe issues that affect the stability and reliability
of power conversion systems. The space vector modulation (SVM) technique is widely used …

Open-circuit fault-tolerant control for a three-phase current-fed dual active bridge dc–dc converter

TT Le, MK Nguyen, TD Duong… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Fault-tolerant methods have been recognized for improving the reliability of multiphase
bidirectional dc–dc converters, including current-fed and voltage-fed dual active bridge …

Non-isolated fourth-order boost DC-DC converter for power management in low voltage low power dc grids: design and interaction analysis

A Kulshreshtha, AR Saxena, M Veerachary - IEEE Access, 2020 - ieeexplore.ieee.org
In this paper, a minimum-phase response fourth-order boost dc-dc converter (FBDC)
exhibiting continuous input and output current is proposed. A voltage-mode controller is …

Protection of low voltage DC microgrids: A review

F Mohan, N Sasidharan - Electric Power Systems Research, 2023 - Elsevier
The technological escalation in DC power generation from renewable energy sources has