The impact of implant‐related characteristics on dental implant blooming: An in vitro study

M Tarce, A de Greef, P Lahoud… - Clinical Oral …, 2022 - Wiley Online Library
Aim To assess, in vitro, variables potentially influencing implant blooming using a human‐
like imaging phantom and 3D‐printed mandibles. Material and Methods Sixty implants were …

Impact of the blooming artefact on dental implant dimensions in 13 cone-beam computed tomography devices

VA Wanderley, K de Faria Vasconcelos… - International journal of …, 2021 - Springer
Background The purpose of this study was to objectively assess dimensional alteration
(blooming artefact) on dental implant using 13 cone-beam computed tomography (CBCT) …

Does cone-beam CT convex triangular field of view influence the image shape distortion of high-density materials?

D Cascante-Sequeira, F Coelho-Silva… - Dentomaxillofacial …, 2023 - academic.oup.com
Objectives: To assess the distortion of high-density materials using two CBCT devices
presenting convex triangular and cylindrical fields of view (FOVs). Methods and materials …

Distortion or magnification? An in vitro cone-beam CT study of dimensional changes of objects with different compositions

F Coelho-Silva, H Gaêta-Araujo… - Dentomaxillofacial …, 2021 - academic.oup.com
Objectives: To assess whether dimensional changes occur as shape distortion (unevenly),
contraction or magnification (evenly) in cone beam computed tomography (CBCT) …

Know your way around acute unenhanced CT during global iodinated contrast crisis: a refresher to ED radiologists

W Abdellatif, V Vasan, FU Kay, A Kohli, S Abbara… - Emergency …, 2022 - Springer
Due to a contrast shortage crisis resulting from the decreased supply of iodinated contrast
agents, the American College of Radiology (ACR) has issued a guidance statement …

Assessment of the root filling volume in C-shaped root canal on cone-beam CT and micro-CT in relation to nano-CT

AP Candemil, JF Mazzi-Chaves, ML Oliveira… - Clinical Oral …, 2023 - Springer
Aim To assess the observed volume of filled C-shaped root canals from different CBCT and
micro-CT having nano-CT as a reference. Materials and methods Twelve extracted …

Comparison of the expression of the volumetric alteration artifact in cylindrical and triangular fields of view in two cone-beam computed tomography devices

D Cascante-Sequeira, F Coelho-Silva… - Clinical Oral …, 2022 - Springer
Objective To compare the expression of the volumetric alteration (VA) artifact between
cylindrical and convex triangular fields of view (FOVs) using high-density materials in …

Comparison of artifact values of prosthodontic materials with 2 different cone beam computed tomography devices

ME Naralan, A Ozdogan, MT Guller… - The Journal of Prosthetic …, 2023 - Elsevier
Statement of problem Prosthodontic materials may cause unexpected artifacts in cone beam
computed tomography (CBCT) images, but studies quantifying these artifacts are sparse …

The Influence of Slice Thickness, Sharpness, and Contrast Adjustments on Inferior Alveolar Canal Segmentation on Cone-Beam Computed Tomography Scans: A …

J Issa, A Riad, R Olszewski… - Journal of Personalized …, 2023 - mdpi.com
This retrospective study aims to investigate the impact of cone-beam computed tomography
(CBCT) viewing parameters such as contrast, slice thickness, and sharpness on the …

Comparison of the amount of artifacts induced by zirconium and titanium implants in cone-beam computed tomography images

A Shokri, F Vafaee, L Haghighat, S Shahabi… - BMC Medical …, 2022 - Springer
Background This study aimed to compare the amount of artifacts induced by the titanium and
zirconium implants on cone-beam computed tomography (CBCT) and assess the effect of …