Progress and perspectives on weak-value amplification

L Xu, L Zhang - Progress in Quantum Electronics, 2024 - Elsevier
Weak-value amplification (WVA) is a metrological protocol that effectively amplifies ultra-
small physical effects, making it highly applicable in the fields of quantum sensing and …

[HTML][HTML] Enhanced on-chip phase measurement by inverse weak value amplification

M Song, J Steinmetz, Y Zhang, J Nauriyal… - Nature …, 2021 - nature.com
Optical interferometry plays an essential role in precision metrology such as in gravitational
wave detection, gyroscopes, and environmental sensing. Weak value amplification enables …

Optical weak measurement system with common path implementation for label-free biomolecule sensing

Y Zhang, D Li, Y He, Z Shen, Q He - Optics letters, 2016 - opg.optica.org
A reflection-type phase-sensitive weak measurement for biosensing and chemical label-free
sensing is presented. The phase difference between p and s polarizations in total internal …

A chiral sensor based on weak measurement for the determination of Proline enantiomers in diverse measuring circumstances

D Li, T Guan, Y He, F Liu, A Yang, Q He, Z Shen… - Biosensors and …, 2018 - Elsevier
A new chiral sensor based on weak measurement to accurately measure the optical rotation
(OR) has been developed for the estimation of a trace amount of chiral molecule. With the …

Application of quantum weak measurement for glucose concentration detection

D Li, Z Shen, Y He, Y Zhang, Z Chen, H Ma - Applied optics, 2016 - opg.optica.org
A quantum weak measurement scheme based on a Mach–Zehnder interferometer is
proposed to detect the concentration of glucose, bringing this mechanism into the field of …

High-precision temperature measurement based on weak measurement using nematic liquid crystals

H Li, JZ Huang, Y Yu, Y Li, C Fang, G Zeng - Applied Physics Letters, 2018 - pubs.aip.org
High-precision temperature measurements could guarantee temperature difference control
accuracy in research and industrial production. To flexibly achieve high precision and large …

Quantitative detection of the respective concentrations of chiral compounds with weak measurements

L Xie, X Qiu, L Luo, X Liu, Z Li, Z Zhang, J Du… - Applied Physics …, 2017 - pubs.aip.org
In this letter, we determine the respective concentrations of glucose and fructose in the
mixed chiral solution by simultaneously measuring the optical rotation angle (ORA) and the …

Molecular imprinting sensor based on quantum weak measurement

D Li, Q He, Y He, M Xin, Y Zhang, Z Shen - Biosensors and Bioelectronics, 2017 - Elsevier
A new type of sensing protocol, based on a high precision metrology of quantum weak
measurement, was first proposed for molecularly imprinted polymers (MIP) sensor. The …

Optimization of a quantum weak measurement system with its working areas

Y Xu, L Shi, T Guan, C Guo, D Li, Y Yang, X Wang… - Optics …, 2018 - opg.optica.org
Phase-sensitive weak measurement systems have been receiving an increasing amount of
attention. In this paper, we introduce a series of weak measurement working areas. By …

Effects of bonding on the performance of optical fiber strain sensors

I Floris, V Sangiorgio, JM Adam, G Uva… - … Control and Health …, 2021 - Wiley Online Library
The structural health monitoring (SHM) of existing buildings, structures, and infrastructures
has become increasingly important in recent years, while the interest of the scientific …