Making the invisible visible—ultrashort echo time magnetic resonance imaging: technical developments and applications
Magnetic resonance imaging (MRI) uses a large magnetic field and radio waves to generate
images of tissues in the body. Conventional MRI techniques have been developed to image …
images of tissues in the body. Conventional MRI techniques have been developed to image …
Short-T2 MRI: Principles and recent advances
M Weiger, KP Pruessmann - Progress in nuclear magnetic resonance …, 2019 - Elsevier
Among current modalities of biomedical and diagnostic imaging, MRI stands out by virtue of
its versatile contrast obtained without ionizing radiation. However, in various cases, eg …
its versatile contrast obtained without ionizing radiation. However, in various cases, eg …
Optimized 3D ultrashort echo time pulmonary MRI
Purpose To optimize 3D radial ultrashort echo time MRI for high resolution whole‐lung
imaging. Methods 3D radial ultrashort echo time was implemented on a 3T scanner to …
imaging. Methods 3D radial ultrashort echo time was implemented on a 3T scanner to …
Iterative motion‐compensation reconstruction ultra‐short TE (iMoCo UTE) for high‐resolution free‐breathing pulmonary MRI
Purpose To develop a high‐scanning efficiency, motion‐corrected imaging strategy for free‐
breathing pulmonary MRI by combining an iterative motion‐compensation reconstruction …
breathing pulmonary MRI by combining an iterative motion‐compensation reconstruction …
Motion robust high resolution 3D free‐breathing pulmonary MRI using dynamic 3D image self‐navigator
Purpose To achieve motion robust high resolution 3D free‐breathing pulmonary MRI
utilizing a novel dynamic 3D image navigator derived directly from imaging data. Methods …
utilizing a novel dynamic 3D image navigator derived directly from imaging data. Methods …
Self‐gated 3D stack‐of‐spirals UTE pulmonary imaging at 0.55 T
A Javed, R Ramasawmy, K O'Brien… - Magnetic resonance …, 2022 - Wiley Online Library
Purpose To develop an isotropic high‐resolution stack‐of‐spirals UTE sequence for
pulmonary imaging at 0.55 Tesla by leveraging a combination of robust respiratory‐binning …
pulmonary imaging at 0.55 Tesla by leveraging a combination of robust respiratory‐binning …
Ultrashort echo-time magnetic resonance imaging is a sensitive method for the evaluation of early cystic fibrosis lung disease
DJ Roach, Y Crémillieux, RJ Fleck… - Annals of the …, 2016 - atsjournals.org
Rationale: Recent advancements that have been made in magnetic resonance imaging
(MRI) improve our ability to assess pulmonary structure and function in patients with cystic …
(MRI) improve our ability to assess pulmonary structure and function in patients with cystic …
Multi-nuclear magnetic resonance spectroscopy: State of the art and future directions
Y Wei, C Yang, H Jiang, Q Li, F Che, S Wan, S Yao… - Insights into …, 2022 - Springer
With the development of heteronuclear fluorine, sodium, phosphorus, and other probes and
imaging technologies as well as the optimization of magnetic resonance imaging (MRI) …
imaging technologies as well as the optimization of magnetic resonance imaging (MRI) …
The current status and further prospects for lung magnetic resonance imaging in pediatric radiology
FW Hirsch, I Sorge, J Vogel-Claussen, C Roth… - Pediatric …, 2020 - Springer
Lung MRI makes it possible to replace up to 90% of CT examinations with radiation-free
magnetic resonance diagnostics of the lungs without suffering any diagnostic loss. The …
magnetic resonance diagnostics of the lungs without suffering any diagnostic loss. The …
[HTML][HTML] Uncoupling of the profibrotic and hemostatic effects of thrombin in lung fibrosis
Fibrotic lung disease, most notably idiopathic pulmonary fibrosis (IPF), is thought to result
from aberrant wound-healing responses to repetitive lung injury. Increased vascular …
from aberrant wound-healing responses to repetitive lung injury. Increased vascular …