[HTML][HTML] Biotribology of artificial hip joints

F Di Puccio, L Mattei - World journal of orthopedics, 2015 - ncbi.nlm.nih.gov
Hip arthroplasty can be considered one of the major successes of orthopedic surgery, with
more than 350000 replacements performed every year in the United States with a constantly …

Tribology and total hip joint replacement: current concepts in mechanical simulation

S Affatato, M Spinelli, M Zavalloni… - Medical engineering & …, 2008 - Elsevier
Interest in the rheology and effects of interacting surfaces is as ancient as man. This subject
can be represented by a recently coined word: tribology. This term is derived from the Greek …

Wear of CoCrMo alloys used in metal-on-metal hip joints: a tribocorrosion appraisal

S Mischler, AI Munoz - Wear, 2013 - Elsevier
A good biocompatibility, excellent mechanical properties and high corrosion resistance
characterize CoCrMo alloys. Therefore they are widely used for artificial joints in biomedical …

Influence of assembly procedure and material combination on the strength of the taper connection at the head–neck junction of modular hip endoprostheses

A Rehmer, NE Bishop, MM Morlock - Clinical Biomechanics, 2012 - Elsevier
BACKGROUND: A stable fixation between femoral head and endoprosthesis taper is
necessary to prevent relative motions and corrosion at the taper junction. Although the …

Hierarchy of stability factors in reverse shoulder arthroplasty

S Gutiérrez, TS Keller, JC Levy, WE Lee… - Clinical orthopaedics and …, 2008 - Springer
Reverse shoulder arthroplasty is being used more frequently to treat irreparable rotator cuff
tears in the presence of glenohumeral arthritis and instability. To date, however, design …

The 2014 Frank Stinchfield Award: the 'landing zone'for wear and stability in total hip arthroplasty is smaller than we thought: a computational analysis

JM Elkins, JJ Callaghan, TD Brown - Clinical Orthopaedics and …, 2015 - journals.lww.com
Background Positioning of total hip bearings involves tradeoffs, because cup orientations
most favorable in terms of stability are not necessarily ideal in terms of reduction of contact …

Evolution of different designs and wear studies in total hip prosthesis using finite element analysis: A review

C KN, S Bhat N, M Zuber, S Shenoy B - Cogent Engineering, 2022 - Taylor & Francis
In replacement surgery of the hip joint, an implant is replaced into the natural femur which
recreates the articulation and functionally of a natural joint. Total hip replacement is …

Total hip joint prosthesis for in vivo measurement of forces and moments

P Damm, F Graichen, A Rohlmann, A Bender… - Medical engineering & …, 2010 - Elsevier
A new instrumented hip joint prosthesis was developed which allows the in vivo
measurement of the complete contact loads in the joint, ie 3 force and 3 moment …

Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing–systematic review of clinical and epidemiological studies

A Hartmann, F Hannemann, J Lützner, A Seidler… - PLoS …, 2013 - journals.plos.org
Introduction The use of metal-on-metal (MoM) total hip arthroplasty (THA) increased in the
last decades. A release of metal products (ie particles, ions, metallo-organic compounds) in …

[HTML][HTML] Wear and Friction of UHMWPE-on-PEEK OPTIMA™

RM Cowie, A Briscoe, J Fisher, LM Jennings - Journal of the Mechanical …, 2019 - Elsevier
PEEK-OPTIMA™ is being considered as an alternative bearing material to cobalt chrome in
the femoral component of total knee replacement to provide a metal-free implant. The aim of …