Maximum-likelihood methods for processing signals from gamma-ray detectors
In any gamma-ray detector, each event produces electrical signals on one or more circuit
elements. From these signals, we may wish to determine the presence of an interaction; …
elements. From these signals, we may wish to determine the presence of an interaction; …
Maximum-likelihood estimation with a contracting-grid search algorithm
JY Hesterman, L Caucci, MA Kupinski… - IEEE transactions on …, 2010 - ieeexplore.ieee.org
A fast search algorithm capable of operating in multi-dimensional spaces is introduced. As a
sample application, we demonstrate its utility in the 2D and 3D maximum-likelihood position …
sample application, we demonstrate its utility in the 2D and 3D maximum-likelihood position …
Calibration method for ML estimation of 3D interaction position in a thick gamma-ray detector
WCJ Hunter, HH Barrett… - IEEE transactions on …, 2009 - ieeexplore.ieee.org
High-energy (> 100 keV) photon detectors are often made thick relative to their lateral
resolution in order to improve their photon-detection efficiency. To avoid issues of parallax …
resolution in order to improve their photon-detection efficiency. To avoid issues of parallax …
Use of Cramer–Rao lower bound for performance evaluation of different monolithic crystal PET detector designs
X Li, WCJ Hunter, TK Lewellen… - IEEE transactions on …, 2011 - ieeexplore.ieee.org
We have previously reported on continuous miniature crystal element (cMiCE) PET
detectors that provide depth of interaction (DOI) positioning capability. A key component of …
detectors that provide depth of interaction (DOI) positioning capability. A key component of …
Comparison of detector intrinsic spatial resolution characteristics for sensor on the entrance surface and conventional readout designs
RS Miyaoka, X Li, C Lockhart… - IEEE transactions on …, 2010 - ieeexplore.ieee.org
We report on a high resolution, monolithic crystal PET detector design concept that provides
depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on …
depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on …
List-mode MLEM image reconstruction from 3D ML position estimates
L Caucci, WCJ Hunter, LR Furenlid… - IEEE Nuclear Science …, 2010 - ieeexplore.ieee.org
Current thick detectors used in medical imaging allow recording many attributes, such as the
3D location of interaction within the scintillation crystal and the amount of energy deposited …
3D location of interaction within the scintillation crystal and the amount of energy deposited …
NaI gamma camera performance for high energies: Effects of crystal thickness, photomultiplier tube geometry and light guide thickness
V Cosmi, B Wang, MC Goorden… - Medical Physics, 2024 - Wiley Online Library
Background Gamma camera imaging, including single photon emission computed
tomography (SPECT), is crucial for research, diagnostics, and radionuclide therapy. Gamma …
tomography (SPECT), is crucial for research, diagnostics, and radionuclide therapy. Gamma …
Towards continuous-to-continuous 3D imaging in the real world
Imaging systems are often modeled as continuous-to-discrete mappings that map the object
(ie a function of continuous variables such as space, time, energy, wavelength, etc) to a finite …
(ie a function of continuous variables such as space, time, energy, wavelength, etc) to a finite …
ModPET: Novel applications of scintillation cameras to preclinical PET
SK Moore - 2011 - search.proquest.com
We have designed, developed, and assessed a novel preclinical positron emission
tomography (PET) imaging system named ModPET. The system was developed using …
tomography (PET) imaging system named ModPET. The system was developed using …
AdaptiSPECT: a preclinical imaging system
C Chaix - 2015 - search.proquest.com
This dissertation addresses the design, development, calibration and performance
evaluation of a pre-clinical imaging system called AdaptiSPECT. Single-Photon Emission …
evaluation of a pre-clinical imaging system called AdaptiSPECT. Single-Photon Emission …