Reflectance photoplethysmography as noninvasive monitoring of tissue blood perfusion

TY Abay, PA Kyriacou - IEEE Transactions on Biomedical …, 2015 - ieeexplore.ieee.org
In the last decades, photoplethysmography (PPG) has been used as a noninvasive
technique for monitoring arterial oxygen saturation by pulse oximetry (PO), whereas near …

Pulse oximetry based on photoplethysmography imaging with red and green light: Calibratability and challenges

A Moço, W Verkruysse - Journal of clinical monitoring and computing, 2021 - Springer
Remotely measuring the arterial blood oxygen saturation (SpO 2) in visible light (Vis)
involves different probing depths, which may compromise calibratibility. This paper assesses …

Towards reliable driver drowsiness detection leveraging wearables

Y Cao, F Li, X Liu, S Yang, Y Wang - ACM Transactions on Sensor …, 2023 - dl.acm.org
Driver drowsiness is a significant factor in road crashes. However, existing solutions for
driver drowsiness detection have major drawbacks of requiring special hardware …

Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions

TY Abay, PA Kyriacou - Journal of clinical monitoring and computing, 2018 - Springer
Photoplethysmography (PPG) is an optical technique that measures blood volume
variations. The main application of dual-wavelength PPG is pulse oximetry, in which the …

Effects of contact pressure in reflectance photoplethysmography in an in vitro tissue-vessel phantom

JM May, E Mejía-Mejía, M Nomoni, K Budidha, C Choi… - Sensors, 2021 - mdpi.com
With the continued development and rapid growth of wearable technologies, PPG has
become increasingly common in everyday consumer devices such as smartphones and …

In vivo investigation of ear canal pulse oximetry during hypothermia

K Budidha, PA Kyriacou - Journal of Clinical Monitoring and Computing, 2018 - Springer
Pulse oximeters rely on the technique of photoplethysmography (PPG) to estimate arterial
oxygen saturation (SpO _2 2). In conditions of poor peripheral perfusion such as …

Comparison of foot finding methods for deriving instantaneous pulse rates from photoplethysmographic signals

MC Hemon, JP Phillips - Journal of clinical monitoring and computing, 2016 - Springer
The suitability of different methods of finding the foot point of a pulse as measured using
earlobe photoplethysmography during stationary conditions was investigated. Instantaneous …

Design and development of a modular, multichannel photoplethysmography system

K Budidha, V Rybynok… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
In this paper, we present the design, development, and validation of amodular
photoplethysmography (PPG) system called ZenPPG. This portable, dual-channel system …

The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation

K Budidha, PA Kyriacou - Physiological measurement, 2014 - iopscience.iop.org
For the last two decades, pulse oximetry has been used as a standard procedure for
monitoring arterial oxygen saturation (SpO 2). However, SpO 2 measurements made from …

Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study

M Hickey, JP Phillips, PA Kyriacou - Journal of clinical monitoring and …, 2016 - Springer
A hand-elevation study was carried out in the laboratory in order to alter peripheral blood
flow with the aim of increasing understanding of factors affecting the morphology of …