Power systems with high renewable energy sources: A review of inertia and frequency control strategies over time

A Fernández-Guillamón, E Gómez-Lázaro… - … and Sustainable Energy …, 2019 - Elsevier
Traditionally, inertia in power systems has been determined by considering all the rotating
masses directly connected to the grid. During the last decade, the integration of renewable …

Inertia response and frequency control techniques for renewable energy sources: A review

M Dreidy, H Mokhlis, S Mekhilef - Renewable and sustainable energy …, 2017 - Elsevier
Preservation of the environment has become the main motivation to integrate more
renewable energy sources (RESs) in electrical networks. However, several technical issues …

High-level penetration of renewable energy sources into grid utility: Challenges and solutions

MS Alam, FS Al-Ismail, A Salem, MA Abido - IEEE access, 2020 - ieeexplore.ieee.org
The utilization of renewable energy sources (RESs) has become significant throughout the
world, especially over the last two decades. Although high-level RESs penetration reduces …

Impact of low rotational inertia on power system stability and operation

A Ulbig, TS Borsche, G Andersson - IFAC Proceedings Volumes, 2014 - Elsevier
Large-scale deployment of Renewable Energy Sources (RES) has led to significant
generation shares of variable RES in power systems worldwide. RES units, notably inverter …

Virtual synchronous generators: A survey and new perspectives

H Bevrani, T Ise, Y Miura - International Journal of Electrical Power & …, 2014 - Elsevier
In comparison of the conventional bulk power plants, in which the synchronous machines
dominate, the distributed generator (DG) units have either very small or no rotating mass …

State-of-the-art review on frequency response of wind power plants in power systems

Z Wu, W Gao, T Gao, W Yan, H Zhang… - Journal of Modern …, 2018 - ieeexplore.ieee.org
With an increasing penetration of wind power in the modern electrical grid, the increasing
replacement of large conventional synchronous generators by wind power plants will …

Droop control as an alternative inertial response strategy for the synthetic inertia on wind turbines

J Van de Vyver, JDM De Kooning… - … on Power Systems, 2015 - ieeexplore.ieee.org
In several countries, the wind power penetration increased tremendously in recent years. To
ensure the proper functioning of the power system, some grid operators already require the …

A literature survey on load–frequency control for conventional and distribution generation power systems

SK Pandey, SR Mohanty, N Kishor - Renewable and Sustainable Energy …, 2013 - Elsevier
In this paper an extensive literature review on load–frequency control (LFC) problem in
power system has been highlighted. The various configuration of power system models and …

Feedforward frequency deviation control in PLL for fast inertial response of DFIG-based wind turbines

D Zhu, X Guo, B Tang, J Hu, X Zou… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
Inertial response is gradually becoming a mandatory requirement for wind turbine (WT)
integrated into power system. However, most inertia control strategies are implemented in …

Primary frequency regulation by deloaded wind turbines using variable droop

KV Vidyanandan, N Senroy - IEEE transactions on Power …, 2012 - ieeexplore.ieee.org
This paper introduces a method to improve the primary frequency contribution of grid
connected variable speed wind turbine generators (WTGs). Using their energy reserve …