Research and Technologies for next-generation high-temperature data centers–State-of-the-arts and future perspectives
Data centers have attracted increasing attention worldwide over the last decades due to
their high energy consumption. Cooling accounts for about 30–40% of the total energy …
their high energy consumption. Cooling accounts for about 30–40% of the total energy …
A review of data center cooling technology, operating conditions and the corresponding low-grade waste heat recovery opportunities
The depletion of the world's limited reservoirs of fossil fuels, the worldwide impact of global
warming and the high cost of energy are among the primary issues driving a renewed …
warming and the high cost of energy are among the primary issues driving a renewed …
Cooling of server electronics: A design review of existing technology
AC Kheirabadi, D Groulx - Applied Thermal Engineering, 2016 - Elsevier
This review quantitatively examines and compares the heat transfer characteristics of
several cooling technologies with potential application in the server electronics industry …
several cooling technologies with potential application in the server electronics industry …
Cooling systems in data centers: state of art and emerging technologies
A Capozzoli, G Primiceri - Energy Procedia, 2015 - Elsevier
The growing number, size, complexity and energy density of data centers due to increasing
demand for storage, networking and computation bring a considerable energy challenge …
demand for storage, networking and computation bring a considerable energy challenge …
A review on data centre cooling system using heat pipe technology
X Wang, Q Wen, J Yang, J Xiang, Z Wang… - … Informatics and Systems, 2022 - Elsevier
Heat pipe, a high efficient, cost effective and reliable device, is considered one of the most
promising passive technologies for cooling data centres. Aiming to provide comprehensive …
promising passive technologies for cooling data centres. Aiming to provide comprehensive …
Two-phase spray cooling for high ambient temperature data centers: Evaluation of system performance
A lab-scale spray cooled rack system with a server and simulated heaters, operating with
near-ambient temperature coolant of approximately 30° C, was developed for data center …
near-ambient temperature coolant of approximately 30° C, was developed for data center …
Strategies for improving the sustainability of data centers via energy mix, energy conservation, and circular energy
Information and communication technologies (ICT) are increasingly permeating our daily life
and we ever more commit our data to the cloud. Events like the covid-19 pandemic put an …
and we ever more commit our data to the cloud. Events like the covid-19 pandemic put an …
Data center energy conservation study utilizing loop heat pipes as a chip-level cooling technique and its industrial application
ZH Xue, BC Ai, W Qu - Applied Thermal Engineering, 2023 - Elsevier
The thermal management and energy consumption for data centers became an increasing
challenge due to a significant increase in their number, size and power density in modern …
challenge due to a significant increase in their number, size and power density in modern …
Application of separated heat pipe system in data center cooling
T Ding, Z guang He, T Hao, Z Li - Applied Thermal Engineering, 2016 - Elsevier
This paper mainly studies the application of separated heat pipe system on data center
cooling. Separated heat pipe system mainly consists of four parts: evaporator, condenser …
cooling. Separated heat pipe system mainly consists of four parts: evaporator, condenser …