Uniqueness of tomography with unknown view angles

S Basu, Y Bresler - IEEE transactions on image processing, 2000 - ieeexplore.ieee.org
In the standard two-dimensional (2-D) parallel beam tomographic formulation, it is assumed
that the angles at which the projections were acquired are known. In certain situations …

Ab initio reconstruction and experimental design for cryo electron microscopy

PC Doerschuk, JE Johnson - IEEE Transactions on Information …, 2000 - ieeexplore.ieee.org
A statistical model for the object and the complete image formation process in the cryo
electron microscopy of viruses is presented. Using this model, maximum-likelihood …

A multiresolution approach to orientation assignment in 3D electron microscopy of single particles

COS Sorzano, S Jonić, C El-Bez, JM Carazo… - Journal of structural …, 2004 - Elsevier
Three-dimensional (3D) electron microscopy (3DEM) aims at the determination of the spatial
distribution of the Coulomb potential of macromolecular complexes. The 3D reconstruction …

Structure and view estimation for tomographic reconstruction: A Bayesian approach

SP Mallick, S Agarwal, DJ Kriegman… - 2006 IEEE Computer …, 2006 - ieeexplore.ieee.org
This paper addresses the problem of reconstructing the density of a scene from multiple
projection images produced by modalities such as x-ray, electron microscopy, etc. where an …

Markerless alignment in electron tomography

SS Brandt - Electron tomography: methods for three-dimensional …, 2006 - Springer
In computing high-accuracy reconstructions from transmission electron microscope (TEM) tilt
series, image alignment currently has an important role. Though most are automated …

Spline-based image-to-volume registration for three-dimensional electron microscopy

S Jonić, COS Sorzano, P Thevenaz, C El-Bez… - Ultramicroscopy, 2005 - Elsevier
This paper presents an algorithm based on a continuous framework for a posteriori angular
and translational assignment in three-dimensional electron microscopy (3DEM) of single …

Exact reduced-complexity maximum likelihood reconstruction of multiple 3-D objects from unlabeled unoriented 2-D projections and electron microscopy of viruses

J Lee, PC Doerschuk… - IEEE transactions on image …, 2007 - ieeexplore.ieee.org
In cryo-electron microscopy, the data is comprised of noisy 2-D projection images of the 3-D
electron scattering intensity of the object where the orientation of the projections is unknown …

Estimating view parameters from random projections for tomography using spherical mds

Y Fang, S Murugappan, K Ramani - BMC medical imaging, 2010 - Springer
Background During the past decade, the computed tomography has been successfully
applied to various fields especially in medicine. The estimation of view angles for projections …

Sinogram denoising of cryo-electron microscopy images

T Mielikäinen, J Ravantti - … Conference on Computational Science and Its …, 2005 - Springer
Cryo-electron microscopy has recently been recognized as a useful alternative to obtain
three-dimensional density maps of macromolecular complexes, especially when …

A two exposures technique of electron tomography from projections with random orientations and a quasi-Boolean angular reconstitution

PL Bellon, S Lanzavecchia, V Scatturin - Ultramicroscopy, 1998 - Elsevier
The reconstruction of three-dimensional structures of macromolecular assemblies from
projections with random orientation is commonly based on the detection of lines shared …