A review on power electronics technologies for power quality improvement
Nowadays, new challenges arise relating to the compensation of power quality problems,
where the introduction of innovative solutions based on power electronics is of paramount …
where the introduction of innovative solutions based on power electronics is of paramount …
Active currents, power factor, and apparent power for practical power delivery systems
M Malengret, CT Gaunt - IEEE Access, 2020 - ieeexplore.ieee.org
Concepts of apparent power and power factor as measures of a system's power delivery
capability are over a century old but have not been defined in one general, rigorous and …
capability are over a century old but have not been defined in one general, rigorous and …
Implementation of a novel hybrid UPQC topology endowed with an isolated bidirectional DC–DC converter at DC link
This paper introduces an original hybrid unified power quality conditioner (HUPQC)
topology as an alternative solution to electrical power quality problems. The proposed …
topology as an alternative solution to electrical power quality problems. The proposed …
Three-phase UPQC topology based on quadruple-active-bridge
J Han, X Li, Y Jiang, S Gong - IEEE Access, 2020 - ieeexplore.ieee.org
In this study, a three-phase unified power quality conditioner (UPQC) topology based on a
quadruple-active-bridge (QAB) is presented as an attractive solution to power quality issues …
quadruple-active-bridge (QAB) is presented as an attractive solution to power quality issues …
Optimal design and decoupling control of series DC-link voltages for quadruple-active-bridge based UPQC
J Han, X Li, Y Sun, S Gong, S Huang - … Journal of Electrical Power & Energy …, 2022 - Elsevier
This study presents an optimal design and decoupling control scheme of the series DC-link
voltages for a quadruple-active-bridge (QAB) based unified power quality conditioner …
voltages for a quadruple-active-bridge (QAB) based unified power quality conditioner …
Fuel cell integrated unified power quality conditioner for voltage and current reparation in four‐wire distribution grid
CK Sundarabalan, Y Puttagunta, V Vignesh - IET Smart Grid, 2019 - Wiley Online Library
Electrical and electronic devices, when exposed to one or more power quality problems, are
prone to failure. This study aims to enhance the quality of power in three‐phase four‐wire …
prone to failure. This study aims to enhance the quality of power in three‐phase four‐wire …
Quadruple-active-bridge based unified power quality conditioner-L with fault current limiting capability
J Han, X Li, Y Sun, S Gong, S Huang - Electric Power Systems Research, 2022 - Elsevier
This study presents a quadruple-active-bridge (QAB) based unified power quality
conditioner (UPQC) to improve the power quality and limit the fault currents simultaneously …
conditioner (UPQC) to improve the power quality and limit the fault currents simultaneously …
Optimal UPQC location in power distribution network via merging genetic and dragonfly algorithm
K Gaddala, P Sangameswara Raju - Evolutionary Intelligence, 2022 - Springer
Nowadays, flexible alternating current transmission system devices, particularly unified
power quality conditioner (UPQC) are found to have significant impacts on stability of rising …
power quality conditioner (UPQC) are found to have significant impacts on stability of rising …
Total harmonic distortion reduction in a power grid: A UPQC based approach
This study shows a novel design for a unified power quality conditioner (UPQC) to improve
the power quality. The designed UPQC has two active power filters (APF) in shunt and …
the power quality. The designed UPQC has two active power filters (APF) in shunt and …
Second-order sliding-mode control for three-level H-bridge-based unified power quality conditioner with vanilla feedforward neural network
V Muneer, A Bhattacharya… - IEEE Journal of Emerging …, 2022 - ieeexplore.ieee.org
This article proposes a modified three-wire three-level H-bridge-based unified power quality
conditioner (UPQC) without any transformer in the shunt part and controlled by using second …
conditioner (UPQC) without any transformer in the shunt part and controlled by using second …