[PDF][PDF] Fuzzy controller based grid integration of hybrid solar photovoltaic and DFIG wind energy system to improve power quality

KL Shenoy, CG Nayak, RP Mandi - Appl. Math. Inf. Sci, 2019 - naturalspublishing.com
This paper is focused on grid integration of a hybrid photovoltaic (PV) and doubly fed
induction generator (DFIG) based wind energy system. An intelligent controller was …

[PDF][PDF] Application of Artificial Intelligence to DFIG based wind farm for Reactive Power Compensation

P Jyothi, RBR Prakash, PS Varma - International Journal Of …, 2020 - academia.edu
Doubly Fed Induction Generators are mainly used in the wind applications. In this paper, a
new method for reactive power compensation in wind farms is proposed by using …

System congestion criteria for interconnection of WPP through VSC‐HVDC

MA Rios, EG Guama - IET Generation, Transmission & …, 2019 - Wiley Online Library
The growth of utilisation of wind power plants (WPP) in power systems placed at long
distance of the transmission power system has shown that the best connecting alternatives …

Modeling and Simulation of Crowbar Protection Technique for Doubly Fed Induction Generator under Symmetrical Fault Condition

R Goni, M Salunke, AB Raju - 2024 3rd International …, 2024 - ieeexplore.ieee.org
This paper investigates the protection schemes for a Doubly fed induction generator (DFIG)
when subjected to a fault. A Crowbar protection technique is proposed to mitigate the effects …

DFIG based Power Generation Under Variable Wind Speed Using Fuzzy Controller

KL Shenoy, DK Pai, J Nayak… - 2024 Asia Pacific …, 2024 - ieeexplore.ieee.org
The utilization of fossil fuels peaked worldwide after the Industrial Revolution. Two
significant issues have emerged in recent years: the depletion of fossil fuel reserves and …

Fault ride through capability enhancement of doubly fed wind generator using hybrid protection circuits

B Tipo, J Li, B Qin - 2019 IEEE 8th International Conference on …, 2019 - ieeexplore.ieee.org
This paper presents a new FRT control strategy to improve the dynamic response of doubly
fed induction generator based wind turbine (DFIG-WT) during grid fault. The proposed …

Line Faults Analysis of DFIG Driven by Wind Turbine

MM Thabit, H Elzoghby… - 2019 IEEE Conference on …, 2019 - ieeexplore.ieee.org
Doubly-Fed Induction Generators (DFIGs) are growing rapidly in modern variable speed
wind turbines due to their various advantages such as ability of decoupling the control of …

Soporte de tensión mediante enlace HVDC-VSC y conexión de recurso eólico

EG Guamá Erira - 2018 - repositorio.uniandes.edu.co
Los estudios acerca de la utilización de energía eólica en sistemas de potencia ubicados a
grandes distancias del centro de carga han mostrado que la mejor alternativa para …