A review on corrosion detection and protection of existing reinforced concrete (RC) structures

JY Hu, SS Zhang, E Chen, WG Li - Construction and Building Materials, 2022 - Elsevier
Performance deterioration of existing reinforced concrete (RC) structures due to corrosion of
inside steel reinforcement has been a worldwide issue for long, in particular for RC …

[HTML][HTML] Robust numerical solution for assessing corrosion of reinforced concrete structures under external power supply

B Dong, Y Yu, Y Feng, D Wu, G Zhao, A Liu… - Engineering Structures, 2023 - Elsevier
Impressing current is a popular technique to adjust corrosion behaviors of structures, both in
academic investigation and engineering practice. Focusing on the specific problem, this …

Corrosion inhibition mechanism of phosphates for early-age reinforced mortar in the presence of chlorides

DM Bastidas, M Criado, S Fajardo, A La Iglesia… - Cement and Concrete …, 2015 - Elsevier
A study was performed on the corrosion-inhibition mechanism of three phosphate
compounds (sodium monofluorophosphate, disodium hydrogen phosphate and trisodium …

An efficient green ionic liquid for the corrosion inhibition of reinforcement steel in neutral and alkaline highly saline simulated concrete pore solutions

MH Sliem, AB Radwan, FS Mohamed, NA Alnuaimi… - Scientific Reports, 2020 - nature.com
The effect of the green ionic liquid compound, Quaternium-32 (Q-32), on the corrosion
inhibition performance of reinforcement steel, in a simulated concrete pore solution, was …

Combined impressed current cathodic protection and FRCM strengthening for corrosion-prone concrete structures

M Su, L Wei, JH Zhu, T Ueda, G Guo… - Journal of Composites for …, 2019 - ascelibrary.org
This study introduces the use of the combined impressed current cathodic protection–
structural strengthening (ICCP-SS) as a technique for repairing reinforced concrete …

Understanding the sulfate attack of Portland cement–based materials exposed to applied electric fields: Mineralogical alteration and migration behavior of ionic …

C Li, Z Jiang, RJ Myers, Q Chen, M Wu, J Li… - Cement and Concrete …, 2020 - Elsevier
The magnesium and sodium sulfate attacks on Portland cement paste in the presence of
applied electric fields were studied, and the mineralogical alterations were investigated by …

Comparative study of three sodium phosphates as corrosion inhibitors for steel reinforcements

DM Bastidas, M Criado, VM La Iglesia, S Fajardo… - Cement and Concrete …, 2013 - Elsevier
A comparative study was performed on the inhibition of steel reinforcement corrosion using
three soluble phosphates: sodium monofluorophosphate (Na 2 PO 3 F), disodium hydrogen …

Effect of duty cycle and frequency of pulse current on bidirectional electro-migration rehabilitation

D Li, Y Sun, K Du, Q Guo, C Wang, Y Fang, H Yu… - … and Building Materials, 2024 - Elsevier
In this paper, a new approach of bidirectional electro-migration rehabilitation (BIEM) using
pulse currents was proposed. The effect of the duty cycle and frequency of the square wave …

Multi-species reactive transport modeling of electrochemical corrosion control in saturated concrete structures including electrode reactions and thermodynamic …

B Guo, G Qiao, D Li, J Ou - Construction and Building Materials, 2021 - Elsevier
The ionic migration in concrete determines the efficiency of electrochemical corrosion
control of reinforced concrete structures, such as electrochemical chloride extraction …

Significance of π–electrons in the design of corrosion inhibitors for carbon steel in simulated concrete pore solution

A Mohamed, DP Visco, DM Bastidas - Corrosion, 2021 - meridian.allenpress.com
Chloride-induced corrosion of carbon steel reinforcements is one of the most important
failure mechanisms of reinforced concrete structures. Organic corrosion inhibitors containing …