Influence of a soft story on the seismic response of non-structural components
V Pesaralanka, SP Challagulla, F Vicencio… - Sustainability, 2023 - mdpi.com
Multi-story, reinforced-concrete (RC) building structures with soft stories are highly
vulnerable to damage due to earthquake loads. The soft story causes a significant stiffness …
vulnerable to damage due to earthquake loads. The soft story causes a significant stiffness …
Assessment of the diaphragm condition for floor systems used in urban buildings
A Tena-Colunga, KL Chinchilla-Portillo… - Engineering …, 2015 - Elsevier
A study devoted to define the diaphragm condition using linear-elastic analyses for
structures with the most widely used floor systems in Mexico (two-way ribbed RC slabs …
structures with the most widely used floor systems in Mexico (two-way ribbed RC slabs …
[HTML][HTML] Influence and effectiveness of horizontal diaphragms and cladding wall panels on the seismic behaviour of precast RC industrial buildings
L Ostetto, R Sousa, P Fernandes, H Rodrigues - Engineering Structures, 2023 - Elsevier
The seismic behaviour of precast reinforced concrete industrial structures has been
extensively investigated in recent decades, especially after the damage caused by recent …
extensively investigated in recent decades, especially after the damage caused by recent …
Seismic risk assessment of typical reinforced concrete frame school buildings in Sri Lanka
The assessment of seismic risk for critical and strategic structures like schools and hospitals
remains crucial, even in regions with low seismic activity. Presently, operational school …
remains crucial, even in regions with low seismic activity. Presently, operational school …
[PDF][PDF] Using nonlinear static procedures for seismic assessment of the 3D irregular SPEAR building
This paper presents an appraisal of four nonlinear static procedures (CSM, N2, MPA and
ACSM) employed in seismic assessment of plan-irregular buildings. It uses a three storey …
ACSM) employed in seismic assessment of plan-irregular buildings. It uses a three storey …
Evaluation of seismic torsional response of ductile RC buildings with soft first story
CHBV Hareen, SC Mohan - Structures, 2021 - Elsevier
This study investigates the inelastic torsional response of plan asymmetric ductile RC
buildings with a soft first story. The buildings of Rectangular, L, T, and U plan shapes are …
buildings with a soft first story. The buildings of Rectangular, L, T, and U plan shapes are …
Experimental study on in-plane behavior of composite frame slabs and the influence of out-of-plane effect
This paper experimentally investigated the in-plane behavior of a steel–concrete composite
frame slab under cyclic loading by considering the influence of the out-of-plane effect. A …
frame slab under cyclic loading by considering the influence of the out-of-plane effect. A …
Utilizing Artificial Neural Networks and Random Forests to Forecast the Dynamic Amplification Factors of Non-Structural Components
Soft stories in buildings are well-known to present structural vulnerabilities during seismic
events, and the failure of non-structural components (NSCs) has been evident in past …
events, and the failure of non-structural components (NSCs) has been evident in past …
Evaluación de la flexibilidad elástica de sistemas de piso utilizados en edificios urbanos
A Tena Colunga, KL Chinchilla Portillo… - Ingeniería …, 2013 - scielo.org.mx
Se presenta un estudio analítico en el intervalo elástico lineal, que evalúa el
comportamiento de diafragma de los sistemas de piso más ampliamente utilizados en …
comportamiento de diafragma de los sistemas de piso más ampliamente utilizados en …
[PDF][PDF] Assessing the 3D irregular spear building with nonlinear static procedures
ABSTRACT The employment of Nonlinear Static Procedures (NSP) in the seismic
assessment of existing structures (or design verification of new ones) has gained …