Laser ablation–inductively coupled plasma–mass spectrometry imaging in biology
Elemental imaging gives insight into the fundamental chemical makeup of living organisms.
Every cell on Earth is comprised of a complex and dynamic mixture of the chemical elements …
Every cell on Earth is comprised of a complex and dynamic mixture of the chemical elements …
Inductively coupled plasma mass spectrometry
D Beauchemin - Analytical chemistry, 2008 - ACS Publications
The multielemental ultratrace detection capability of inductively coupled plasma mass
spectrometry (ICPMS) makes it a most powerful technique. With each new version of ICPMS …
spectrometry (ICPMS) makes it a most powerful technique. With each new version of ICPMS …
Traditional calibration methods in atomic spectrometry and new calibration strategies for inductively coupled plasma mass spectrometry
Applications, advantages, and limitations of the traditional external standard calibration,
matrix-matched calibration, internal standardization, and standard additions, as well as the …
matrix-matched calibration, internal standardization, and standard additions, as well as the …
A highly efficient introduction system for single cell-ICP-MS and its application to detection of copper in single human red blood cells
Y Cao, J Feng, L Tang, C Yu, G Mo, B Deng - Talanta, 2020 - Elsevier
A method of simultaneous cell counting and determination of metals in single cells using
time-resolved inductively coupled plasma-mass spectrometry (ICP-MS) was reported. A …
time-resolved inductively coupled plasma-mass spectrometry (ICP-MS) was reported. A …
Kinetic energy discrimination in collision/reaction cell ICP-MS: Theoretical review of principles and limitations
N Yamada - Spectrochimica Acta Part B: Atomic Spectroscopy, 2015 - Elsevier
Kinetic energy discrimination (KED) is one of the means to control cell-formed interferences
in collision/reaction cell ICP-MS, and also a technique to reduce polyatomic ion …
in collision/reaction cell ICP-MS, and also a technique to reduce polyatomic ion …
The determination of trace elements in crude oil and its heavy fractions by atomic spectrometry
C Duyck, N Miekeley, CLP da Silveira… - … Acta Part B: Atomic …, 2007 - Elsevier
A literature review on the determination of trace elements in crude oil and heavy molecular
mass fractions (saturates, aromatics, resins and asphaltenes) by ICP-MS, ICP OES and AAS …
mass fractions (saturates, aromatics, resins and asphaltenes) by ICP-MS, ICP OES and AAS …
Dynamic reaction cell ICP-MS for determination of total As, Cr, Se and V in complex matrices: Still a challenge? A review
S D'Ilio, N Violante, C Majorani, F Petrucci - Analytica Chimica Acta, 2011 - Elsevier
Mass interferences, caused by atomic or polyatomic species and having the same
mass/charge ratio of the analyte, can be a severe limit for a reliable assay of trace and …
mass/charge ratio of the analyte, can be a severe limit for a reliable assay of trace and …
Strategies to overcome interferences in elemental and isotopic geochemical analysis by quadrupole inductively coupled plasma mass spectrometry: A critical …
V Balaram - Rapid Communications in Mass Spectrometry, 2021 - Wiley Online Library
Quadrupole Inductively Coupled Plasma Mass Spectrometry (ICP‐MS) instruments were
introduced into geochemical and mineral exploration laboratories nearly four decades ago …
introduced into geochemical and mineral exploration laboratories nearly four decades ago …
Online microdroplet calibration for accurate nanoparticle quantification in organic matrices
S Harycki, A Gundlach-Graham - Analytical and Bioanalytical Chemistry, 2022 - Springer
Single-particle inductively coupled plasma time-of-flight mass spectrometry (spICP-TOFMS)
is a high-throughput method for the multiplexed analysis of nanoparticles (NPs). However …
is a high-throughput method for the multiplexed analysis of nanoparticles (NPs). However …
Radionuclide determination in environmental samples by inductively coupled plasma mass spectrometry
D Lariviere, VF Taylor, RD Evans, RJ Cornett - Spectrochimica Acta Part B …, 2006 - Elsevier
The determination of naturally occurring and anthropogenic radionuclides in the
environment by inductively coupled plasma mass spectrometry has gained recognition over …
environment by inductively coupled plasma mass spectrometry has gained recognition over …