[HTML][HTML] Test and design of built-up cold-formed steel-lightweight concrete (CFS-LWC) composite beams
Cold-formed steel (CFS) products are extremely versatile and can be used in multiple
applications. To further extend their applicability, this investigation assesses the structural …
applications. To further extend their applicability, this investigation assesses the structural …
Numerical investigation into the buckling behaviour of face-to-face built-up cold-formed stainless steel channel sections under axial compression
Stainless steel is becoming popular as structural members because of its increased
corrosion resistance and durability, compared with carbon steel. In cold-formed steel …
corrosion resistance and durability, compared with carbon steel. In cold-formed steel …
Axial compression behavior of laced cold-formed steel built-up columns with unstiffened angle sections
There are numerous parameters that influence the behavior of built-up steel columns. This
paper reports an experimental investigation carried out on cold-formed steel (CFS) built-up …
paper reports an experimental investigation carried out on cold-formed steel (CFS) built-up …
Intermittently stiffened cold-formed steel GFRP composite lightweight built-up beams: Experimental investigation and performance assessment
Previous attempts to develop lightweight cold-formed steel (CFS) composite sections have
successfully improved their buckling strengths but have been limited to unstiffened profiles …
successfully improved their buckling strengths but have been limited to unstiffened profiles …
Cold-formed ferritic stainless steel closed-section built-up beams: tests and flexural response
This article presents the first experimental study reported on the flexural behaviour of cold-
formed ferritic stainless steel (CFFSS) closed-section built-up beams. Each closed-section …
formed ferritic stainless steel (CFFSS) closed-section built-up beams. Each closed-section …
Axial capacity of back-to-back built-up cold-formed stainless steel unlipped channels-Numerical investigation and parametric study
In cold-formed steel structures, such as trusses, wall frames and portal frames, the use of
back-to-back built-up cold-formed stainless steel unlipped channels as compression …
back-to-back built-up cold-formed stainless steel unlipped channels as compression …
[HTML][HTML] Finite element analysis of behavior and ultimate strength of composite column
LR Ayyasamy, A Mohan, DS Vijayan… - … and Engineering of …, 2022 - degruyter.com
Composite sections are found to be a novel technique in modern day scenario of
construction. This stands tall than the ordinary and conventional type of constructions …
construction. This stands tall than the ordinary and conventional type of constructions …
[PDF][PDF] Finite element modelling of back-to-back built-up cold-formed stainless-steel lipped channels under axial compression
In cold-formed steel structures, such as trusses, wall frames and portal frames, the use 13 of
back-to-back built-up cold-formed stainless-steel lipped channels as compression members …
back-to-back built-up cold-formed stainless-steel lipped channels as compression members …
Development of lightweight CFS composite built-up beams: Tests and flexural response
Although previous attempts for enhancing the buckling resistance of cold-formed steel (CFS)
built-up beams through intermittent stiffening, external stiffening and adoption of concrete as …
built-up beams through intermittent stiffening, external stiffening and adoption of concrete as …
[HTML][HTML] Flexural design of cold-formed steel built-up sections failing by local buckling: Development of generalised direct strength method
This research paper presents a new flexural design approach for cold-formed steel (CFS)
built-up sections failing in local buckling, developed following an extensive numerical …
built-up sections failing in local buckling, developed following an extensive numerical …