Capillary electrophoresis
CA Monnig, RT Kennedy - Analytical chemistry, 1994 - ACS Publications
This is the third fundamental review of capillary electro-phoresis (CE) and micellar
electrokinetic chromatography (MEKC). The focus of this review will be the work which has …
electrokinetic chromatography (MEKC). The focus of this review will be the work which has …
Joule heating in electrokinetic flow
X Xuan - Electrophoresis, 2008 - Wiley Online Library
Electrokinetic flow is an efficient means to manipulate liquids and samples in lab‐on‐a‐chip
devices. It has a number of significant advantages over conventional pressure‐driven flow …
devices. It has a number of significant advantages over conventional pressure‐driven flow …
Peak broadening in capillary zone electrophoresis
B Gaš, M Štědrý, E Kenndler - Electrophoresis, 1997 - Wiley Online Library
A review on peak broadening in capillary zone electrophoresis in free solutions is given
which covers a selection of the literature published on this topic over the period mainly …
which covers a selection of the literature published on this topic over the period mainly …
Solute dispersion by electroosmotic flow through soft microchannels
V Hoshyargar, A Khorami, SN Ashrafizadeh… - Sensors and Actuators B …, 2018 - Elsevier
We study the hydrodynamic dispersion (HD) by electroosmotic flow in soft microchannels.
Considering a fully developed flow in a slit microchannel of low surface potential and …
Considering a fully developed flow in a slit microchannel of low surface potential and …
Unsteady solute dispersion by electrokinetic flow in a polyelectrolyte layer-grafted rectangular microchannel with wall absorption
The dispersion of a neutral solute band by electrokinetic flow in polyelectrolyte layer (PEL)-
grafted rectangular/slit microchannels is theoretically studied. The flow is assumed to be …
grafted rectangular/slit microchannels is theoretically studied. The flow is assumed to be …
Joule heating effects on peak broadening in capillary zone electrophoresis
Abstract Based on Taylor–Aris dispersion theory, a general analytical formula was derived
for the theoretical plate height in capillary zone electrophoresis with the consideration of …
for the theoretical plate height in capillary zone electrophoresis with the consideration of …
Solute band transport in electroosmotic-pressure-driven flow of Carreau–Yasuda fluid over micropillar arrays
In this study, we numerically investigate the transport and dispersion characteristics of a
neutral solute band in a fluid following generalized Carreau–Yasuda constitutive equations …
neutral solute band in a fluid following generalized Carreau–Yasuda constitutive equations …
Electroosmotic fluid motion and late-time solute transport for large zeta potentials
SK Griffiths, RH Nilson - Analytical chemistry, 2000 - ACS Publications
Analytical and numerical methods are employed to determine the electric potential, fluid
velocity, and late-time solute distribution for electroosmotic flow in a tube and channel at ζ …
velocity, and late-time solute distribution for electroosmotic flow in a tube and channel at ζ …
[图书][B] Labs on chip: Principles, design and technology
E Iannone - 2018 - taylorfrancis.com
Labs on Chip: Principles, Design and Technology provides a complete reference for the
complex field of labs on chip in biotechnology. Merging three main areas—fluid dynamics …
complex field of labs on chip in biotechnology. Merging three main areas—fluid dynamics …
Hydrodynamic dispersion due to combined pressure-driven and electroosmotic flow through microchannels with a thin double layer
EK Zholkovskij, JH Masliyah - Analytical chemistry, 2004 - ACS Publications
The hydrodynamic dispersion of a nonadsorbed and nonelectrolyte solute is considered for
the case of a flow driven through a straight microchannel by pressure and electric potential …
the case of a flow driven through a straight microchannel by pressure and electric potential …