On‐chip tunable Memristor‐based flash‐ADC converter for artificial intelligence applications

K Humood, B Mohammad, H Abunahla… - IET Circuits, Devices …, 2020 - Wiley Online Library
This study presents a novel hybrid memristor (MR)‐complementary metal–oxide–
semiconductor‐based flash analogue‐to‐digital converter (ADC). The speed and efficiency …

Evaluation of the Effect of Nonlinearity of the Successive Approximation ADC to the Measurement Error of RMS

AN Serov, NA Serov… - … Symposium on Industrial …, 2018 - ieeexplore.ieee.org
Currently, the digital measurement methods are most often used to measure the root mean
square (RMS) value of a signal. Among the digital measurement methods, the most popular …

Influence of nonlinearity of ADC conversion function on RMS measurement error

AN Serov, NA Serov… - … Conference on Industrial …, 2018 - ieeexplore.ieee.org
Currently, the root mean square value (RMS) is one of the most informative signal
parameters in power networks. To measure the RMS, there is a number of methods based …

Evaluation of the effect of successive approximation ADC nonlinearity on the measurement error of the phase spectrum

AN Serov, NA Serov… - 2018 Renewable Energies …, 2018 - ieeexplore.ieee.org
The phase spectrum is the power quality parameter. The value of this parameter is used for
indirect measurement of phase difference between signal spectral components, active and …

Application of harmonic functions to estimate the active power measurement error caused by ADC nonlinearity and quantization error

AN Serov, AA Shatokhin… - 2021 20th International …, 2021 - ieeexplore.ieee.org
Active power is one of the most important parameters of electrical power grids. To measure
active power the digital measurement methods are currently applied, which are …

Approximation of ADC nonlinearity by a random function in the case of measurement of electric power parameters

AN Serov, AA Shatokhin… - 2020 30th International …, 2020 - ieeexplore.ieee.org
Currently, the most informative parameters of electric power are active, reactive and
apparent power in the considered frequency band. To measure the parameters of active and …

Исследование погрешности измерения действующего значения напряжения, вызванной нелинейностью функции преобразования АЦП

АН Серов, АА Шатохин - Ползуновский вестник, 2013 - cyberleninka.ru
Выполнен сравнительный анализ методов оценки погрешности измерения
действующего значения напряжения, вызванной нелинейностью функции …

Method of estimating of the amplitude spectrum measurement error caused by the ADC nonlinearity

AN Serov, AA Shatokhin… - 2019 XXIX International …, 2019 - ieeexplore.ieee.org
The nonlinearity of the transfer function of the analog-to-digital converter (ADC) is one of the
most important sources of measurement error of parameters of electrical grids. This is due to …

Исследование интегральной нелинейности ацп последовательного приближения и её влияния на погрешность измерения действующего значения …

АН Серов, АА Шатохин - Южно-Сибирский научный вестник, 2013 - elibrary.ru
В статье рассмотрено влияние нелинейности функции преобразования АЦП на
погрешность измерения действующего значения напряжения. Выполнен анализ …

Testing and Modeling of a SAR ADC for Cryogenic Applications

W Norton, Z Wang, BJ Blalock… - 2019 IEEE 62nd …, 2019 - ieeexplore.ieee.org
In this paper, we investigate and model the effects of extreme low temperature on a
commercial mixed-signal device. The measured results are used to develop a black-box …