Modeling and stability analysis of $ LCL $-type grid-connected inverters: A comprehensive overview

Y Han, M Yang, H Li, P Yang, L Xu, EAA Coelho… - IEEE …, 2019 - ieeexplore.ieee.org
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL
filter has been widely adopted to interface between the inverter and the grid for improving …

A systematic review of grid-connected photovoltaic and photovoltaic/thermal systems: Benefits, challenges and mitigation

AK Hamid, NT Mbungu, A Elnady… - Energy & …, 2023 - journals.sagepub.com
Solar energy is the powerhouse where all potential and classified renewable energies lug
their sources. The energy transformation from the Sun to electricity requires an adequate …

Transient stability of voltage-source converters with grid-forming control: A design-oriented study

D Pan, X Wang, F Liu, R Shi - IEEE Journal of Emerging and …, 2019 - ieeexplore.ieee.org
Driven by the large-scale integration of distributed power resources, grid-connected voltage-
source converters (VSCs) are increasingly required to operate as grid-forming units to …

Enhanced transient angle stability control of grid-forming converter based on virtual synchronous generator

M Chen, D Zhou, F Blaabjerg - IEEE Transactions on Industrial …, 2021 - ieeexplore.ieee.org
Attributed to the ability of inertia provision and good regulation performance, the virtual
synchronous generator (VSG) has been proven as a promising solution to the problems …

Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid

D Zhu, S Zhou, X Zou, Y Kang - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
When LCL-type converter is attached to weak grid, its current control and phase-locked loop
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …

Reduced-order models for representing converters in power system studies

Y Gu, N Bottrell, TC Green - IEEE Transactions on Power …, 2017 - ieeexplore.ieee.org
A reduced-order model that preserves physical meaning is important for generating insight
in large-scale power system studies. The conventional model-order reduction for a multiple …

A Capacitor-Current-Feedback Positive Active Damping Control Strategy for LCL-Type Grid-Connected Inverter to Achieve High Robustness

S Li, H Lin - IEEE Transactions on Power Electronics, 2021 - ieeexplore.ieee.org
To guarantee system stability, proportional capacitor-current-feedback (CCF) active
damping control has been widely used in LCL-type grid-connected inverter. However, when …

Robust active damping methods for LCL filter-based grid-connected converters

MB Saïd-Romdhane, MW Naouar… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
Grid-connected converters (GcCs) employ LCL filters instead of simple L filters in order to
meet new grid codes and their on-going changes in the near future. Active damping …

Capacitor-Current Proportional-Integral Positive Feedback Active Damping for LCL-Type Grid-Connected Inverter to Achieve High Robustness Against Grid …

Y He, X Wang, X Ruan, D Pan, X Xu… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Capacitor-current-feedback active damping has been widely used in LCL-type grid-
connected inverters. However, the damping performance is deteriorated due to the negative …

Control of grid-connected voltage-source converters: The relationship between direct-power control and vector-current control

Y Gui, X Wang, F Blaabjerg… - IEEE Industrial Electronics …, 2019 - ieeexplore.ieee.org
This article discusses the mathematical relationship between grid voltage-modulated (GVM)
direct-power control (DPC) and vector-current control (VCC) for three-phase voltage-source …