Modeling and stability analysis of $ LCL $-type grid-connected inverters: A comprehensive overview
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL
filter has been widely adopted to interface between the inverter and the grid for improving …
filter has been widely adopted to interface between the inverter and the grid for improving …
A systematic review of grid-connected photovoltaic and photovoltaic/thermal systems: Benefits, challenges and mitigation
Solar energy is the powerhouse where all potential and classified renewable energies lug
their sources. The energy transformation from the Sun to electricity requires an adequate …
their sources. The energy transformation from the Sun to electricity requires an adequate …
Transient stability of voltage-source converters with grid-forming control: A design-oriented study
Driven by the large-scale integration of distributed power resources, grid-connected voltage-
source converters (VSCs) are increasingly required to operate as grid-forming units to …
source converters (VSCs) are increasingly required to operate as grid-forming units to …
Enhanced transient angle stability control of grid-forming converter based on virtual synchronous generator
Attributed to the ability of inertia provision and good regulation performance, the virtual
synchronous generator (VSG) has been proven as a promising solution to the problems …
synchronous generator (VSG) has been proven as a promising solution to the problems …
Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid
When LCL-type converter is attached to weak grid, its current control and phase-locked loop
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …
Reduced-order models for representing converters in power system studies
A reduced-order model that preserves physical meaning is important for generating insight
in large-scale power system studies. The conventional model-order reduction for a multiple …
in large-scale power system studies. The conventional model-order reduction for a multiple …
A Capacitor-Current-Feedback Positive Active Damping Control Strategy for LCL-Type Grid-Connected Inverter to Achieve High Robustness
S Li, H Lin - IEEE Transactions on Power Electronics, 2021 - ieeexplore.ieee.org
To guarantee system stability, proportional capacitor-current-feedback (CCF) active
damping control has been widely used in LCL-type grid-connected inverter. However, when …
damping control has been widely used in LCL-type grid-connected inverter. However, when …
Robust active damping methods for LCL filter-based grid-connected converters
MB Saïd-Romdhane, MW Naouar… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
Grid-connected converters (GcCs) employ LCL filters instead of simple L filters in order to
meet new grid codes and their on-going changes in the near future. Active damping …
meet new grid codes and their on-going changes in the near future. Active damping …
Capacitor-Current Proportional-Integral Positive Feedback Active Damping for LCL-Type Grid-Connected Inverter to Achieve High Robustness Against Grid …
Capacitor-current-feedback active damping has been widely used in LCL-type grid-
connected inverters. However, the damping performance is deteriorated due to the negative …
connected inverters. However, the damping performance is deteriorated due to the negative …
Control of grid-connected voltage-source converters: The relationship between direct-power control and vector-current control
This article discusses the mathematical relationship between grid voltage-modulated (GVM)
direct-power control (DPC) and vector-current control (VCC) for three-phase voltage-source …
direct-power control (DPC) and vector-current control (VCC) for three-phase voltage-source …