Seismic behavior of a friction-type artificial plastic hinge for the precast beam–column connection

H Huang, M Li, W Zhang, Y Yuan - Archives of Civil and Mechanical …, 2022 - Springer
This paper proposed a replaceable friction-type artificial plastic hinge (FAPH) to connect the
prefabricated concrete members, characterized by direct load transmission and streamlined …

Experimental research on the seismic performance of precast concrete frame with replaceable artificial controllable plastic hinges

H Huang, M Li, Y Yuan, H Bai - Journal of Structural Engineering, 2023 - ascelibrary.org
To satisfy the easy-repair demands of precast concrete (PC) frames after an earthquake, a
PC frame with replaceable artificial controllable plastic hinges (ACPHs) is proposed in this …

A review of the seismic performance behaviour of hybrid precast beam-to-column connections

HH Ghayeb, NHR Sulong, HA Razak, KH Mo… - Archives of Civil and …, 2022 - Springer
In order to withstand challenges such as earthquakes, it is important to appropriately design
the beam-to-column connection of precast structures. Numerous precast connections were …

Experimental investigation of a precast concrete connection with all-steel bamboo-shaped energy dissipaters

CL Wang, Y Liu, X Zheng, J Wu - Engineering Structures, 2019 - Elsevier
To develop a precast concrete frame suitable for high seismic zones, a new precast concrete
beam-column connection with an additional all-steel bamboo-shaped energy dissipater is …

Numerical study on hysteretic behaviour of horizontal-connection and energy-dissipation structures developed for prefabricated shear walls

L Zhu, L Kong, C Zhang - Applied Sciences, 2020 - mdpi.com
Featured Application This developed “double-step” horizontal-connection and energy-
dissipation structure could be used for prefabricated structures such as shear walls and …

An AHP model for multiple-criteria prioritization of seismic retrofit solutions in gravity-designed industrial buildings

F Andreolli, P Bragolusi, C D'Alpaos… - Journal of building …, 2022 - Elsevier
This paper deals with the development of an Analytic Hierarchy Process (AHP) model aimed
at driving decision-making processes when dealing with seismic retrofitting of industrial …

Seismic retrofit of soft-first-story structures using rotational friction dampers

MM Javidan, J Kim - journal of structural engineering, 2019 - ascelibrary.org
In this research a seismic retrofit system consisting of a pin-jointed steel frame and rotational
friction dampers is developed for the seismic retrofit of reinforced concrete soft-first-story …

Comparative evaluation of seismic performance and environmental impact of traditional and dissipation-based retrofitting solutions for precast structures

F Cavalieri, D Bellotti, M Caruso… - Journal of Building …, 2023 - Elsevier
Seismic rehabilitation is crucial to extend the nominal service life and help reduce the
seismic losses of reinforced concrete precast industrial buildings. Along with traditional …

Mechanical behavior of a replaceable energy dissipation device for precast concrete beam-column connections

G Hu, W Huang, H Xie - Journal of Constructional Steel Research, 2020 - Elsevier
A replaceable energy dissipation device for precast concrete beam-column connections is
proposed in this paper, which is comprised by a short length of a H-shaped steel section …

[HTML][HTML] Seismic design and performance of dry-assembled precast structures with adaptable joints

B Dal Lago, P Negro, A Dal Lago - Soil dynamics and earthquake …, 2018 - Elsevier
Previous research projects and post-earthquake field observation showed that dry-
assembled precast frame structures with hinged beams and cantilever columns restrained at …