Optic nerve sheath diameter: present and future perspectives for neurologists and critical care physicians
Background Estimation of intracranial pressure (ICP) may be helpful in the management of
neurological critically ill patients. It has been shown that ultrasonography of the optic nerve …
neurological critically ill patients. It has been shown that ultrasonography of the optic nerve …
Bedside optic nerve ultrasonography for diagnosing increased intracranial pressure: a systematic review and meta-analysis
Background: Optic nerve ultrasonography (optic nerve sheath diameter sonography) has
been proposed as a noninvasive, quick method for diagnosing increased intracranial …
been proposed as a noninvasive, quick method for diagnosing increased intracranial …
Optic nerve sheath diameter assessment by neurosonology: a review of methodologic discrepancies
RRF Stevens, ED Gommer, MJH Aries… - Journal of …, 2021 - Wiley Online Library
Abstract Background and Purpose Reported cutoff values of the optic nerve sheath diameter
(ONSD) for the diagnosis of elevated intracranial pressure (ICP) are inconsistent. This …
(ONSD) for the diagnosis of elevated intracranial pressure (ICP) are inconsistent. This …
The POCUS consult: how point of care ultrasound helps guide medical decision making
JA Rice, J Brewer, T Speaks, C Choi… - … journal of general …, 2021 - Taylor & Francis
Point of care ultrasound (POCUS) allows for rapid, real-time evaluation of cardiovascular
and respiratory pathology. The advent of portable, handheld devices and increased …
and respiratory pathology. The advent of portable, handheld devices and increased …
A proposed framework for cerebral venous congestion
A Arun, MR Amans, N Higgins… - The …, 2022 - journals.sagepub.com
Background While venous congestion in the peripheral vasculature has been described and
accepted, intracranial venous congestion remains poorly understood. The characteristics …
accepted, intracranial venous congestion remains poorly understood. The characteristics …
Quantification of optic nerve and sheath diameter by transorbital sonography: a systematic review and metanalysis
C Schroeder, AH Katsanos, D Richter… - Journal of …, 2020 - Wiley Online Library
ABSTRACT BACKGROUND AND PURPOSE To date, normal values for optic nerve
diameter (OND) and optic nerve sheath diameter (ONSD) for transorbital sonography (TOS) …
diameter (OND) and optic nerve sheath diameter (ONSD) for transorbital sonography (TOS) …
Optical coherence tomography for the diagnosis and monitoring of idiopathic intracranial hypertension
P Albrecht, C Blasberg, M Ringelstein, AK Müller… - Journal of …, 2017 - Springer
The objectives of the study were to investigate the value of optical coherence tomography in
detecting papilledema in patients with idiopathic intracranial hypertension (IIH), a disease …
detecting papilledema in patients with idiopathic intracranial hypertension (IIH), a disease …
Optic nerve sonographic examination to predict raised intracranial pressure in idiopathic intracranial hypertension: the cut-off points
Purpose Monitoring of raised intracranial pressure (ICP) in patients with idiopathic
intracranial hypertension (IIH) is required to prevent secondary optic nerve damage …
intracranial hypertension (IIH) is required to prevent secondary optic nerve damage …
B-mode transorbital ultrasonography for the diagnosis of idiopathic intracranial hypertension: a systematic review and meta-analysis
P Lochner, K Fassbender, S Knodel… - Ultraschall in der …, 2019 - thieme-connect.com
In patients with idiopathic intracranial hypertension (IIH), transorbital sonography (TOS) may
reveal an enlargement of the optic nerve sheath diameter (ONSD) and the presence of optic …
reveal an enlargement of the optic nerve sheath diameter (ONSD) and the presence of optic …
Ocular ultrasonography for diagnosing increased intracranial pressure in patients with severe preeclampsia
GB Simenc, J Ambrozic, K Prokselj, N Tul… - International journal of …, 2018 - Elsevier
Background Ultrasound measurements of optic nerve sheath diameter (ONSD) and optic
disc height (ODH) measured outside pregnancy correlate with intracranial hypertension …
disc height (ODH) measured outside pregnancy correlate with intracranial hypertension …