Capacitive micromachined ultrasonic transducers for medical imaging and therapy
BT Khuri-Yakub, Ö Oralkan - Journal of micromechanics and …, 2011 - iopscience.iop.org
Capacitive micromachined ultrasonic transducers (CMUTs) have been subject to extensive
research for the last two decades. Although they were initially developed for air-coupled …
research for the last two decades. Although they were initially developed for air-coupled …
Monolithic ultrasound fingerprint sensor
This paper presents a 591× 438-DPI ultrasonic fingerprint sensor. The sensor is based on a
piezoelectric micromachined ultrasonic transducer (PMUT) array that is bonded at wafer …
piezoelectric micromachined ultrasonic transducer (PMUT) array that is bonded at wafer …
Capacitive micromachined ultrasonic transducers: Fabrication technology
AS Erguri, Y Huang, X Zhuang… - IEEE transactions on …, 2005 - ieeexplore.ieee.org
Capacitive micromachined ultrasonic transducer (MUT) technology is a prime candidate for
next generation imaging systems. Medical and underwater imaging and the nondestructive …
next generation imaging systems. Medical and underwater imaging and the nondestructive …
Capacitive micromachined ultrasonic transducers: Theory and technology
AS Ergun, GG Yaralioglu… - Journal of aerospace …, 2003 - ascelibrary.org
Capacitive micromachined ultrasonic transducers (CMUTs), introduced about a decade ago,
have been shown to be a good alternative to conventional piezoelectric transducers in …
have been shown to be a good alternative to conventional piezoelectric transducers in …
Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging
IO Wygant, X Zhuang, DT Yeh… - IEEE transactions on …, 2008 - ieeexplore.ieee.org
For three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional
(2D) transducer array to the imaging system's front-end electronics is a challenge because …
(2D) transducer array to the imaging system's front-end electronics is a challenge because …
Volumetric ultrasound imaging using 2-D CMUT arrays
Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a
candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D …
candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D …
An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging
State-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving
ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of …
ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of …
Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging
FL Degertekin, RO Guldiken… - IEEE transactions on …, 2006 - ieeexplore.ieee.org
In this study, a 64-element, 1.15-mm diameter annular-ring capacitive micromachined
ultrasonic transducer (CMUT) array was characterized and used for forward-looking …
ultrasonic transducer (CMUT) array was characterized and used for forward-looking …
Integrated circuits for volumetric ultrasound imaging with 2-D CMUT arrays
Real-time volumetric ultrasound imaging systems require transmit and receive circuitry to
generate ultrasound beams and process received echo signals. The complexity of building …
generate ultrasound beams and process received echo signals. The complexity of building …
Forward-viewing CMUT arrays for medical imaging
This paper reports the design and testing of forward-viewing annular arrays fabricated using
capacitive micromachined ultrasonic transducer (CMUT) technology. Recent research …
capacitive micromachined ultrasonic transducer (CMUT) technology. Recent research …