Assessment of true intraocular pressure: the gap between theory and practical data

E Chihara - Survey of ophthalmology, 2008 - Elsevier
A precise assessment of the intraocular pressure (IOP) is crucial for diagnosis and decision
making regarding treatment modalities in patients with glaucoma. Recent epidemiologic …

The thick and thin of the central corneal thickness in glaucoma

GW Belovay, I Goldberg - Eye, 2018 - nature.com
Central corneal thickness (CCT) is an important parameter in the assessment of any
potential glaucoma patient. While it affects prognosis in ocular hypertension, its value in …

The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann …

PA Tonnu, T Ho, T Newson, A El Sheikh… - British Journal of …, 2005 - bjo.bmj.com
Aims: To evaluate the influence of central corneal thickness (CCT) on intraocular pressure
(IOP) measurements made with the Goldmann applanation tonometer (GAT), Tono-Pen XL …

[HTML][HTML] Ocular rigidity in living human eyes

IG Pallikaris, GD Kymionis, HS Ginis… - … & visual science, 2005 - arvojournals.org
purpose. To measure the rigidity coefficient of a large number of subjects at clinically
encountered intraocular pressures (IOPs) and to examine the possible correlation of ocular …

24-hour monitoring of intraocular pressure in glaucoma management: a retrospective review

E Hughes, P Spry, J Diamond - Journal of glaucoma, 2003 - journals.lww.com
Purpose Diurnal variation in intraocular pressure (IOP) is well recognized, yet important
decisions in glaucoma management are frequently made after 1 or 2 IOP measurements …

Dynamic contour tonometry: presentation of a new tonometer

HE Kanngiesser, C Kniestedt, YCA Robert - Journal of glaucoma, 2005 - journals.lww.com
With tonometers currently in use intraocular pressure is indirectly determined by measuring
a physical quantity related to a specified deformation of the cornea. We present a new …

[HTML][HTML] Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis

C Kaufmann, LM Bachmann… - … ophthalmology & visual …, 2003 - arvojournals.org
purpose. Thinning of the corneal stroma by laser in situ keratomileusis (LASIK) results in
inaccurate low intraocular pressure (IOP) readings by Goldmann applanation tonometry …

The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry

A Kotecha, ET White, JM Shewry… - British Journal of …, 2005 - bjo.bmj.com
Aims: To establish the effects of central corneal thickness (CCT) on intraocular pressure
(IOP) measured with a prototype Pascal dynamic contour tonometer (DCT), to evaluate the …

Ocular pulse amplitude in healthy subjects as measured by dynamic contour tonometry

C Kaufmann, LM Bachmann, YC Robert… - Archives of …, 2006 - jamanetwork.com
Objectives To test whether dynamic contour tonometry yields ocular pulse amplitude (OPA)
measurements that are independent of corneal thickness and curvature, and to assess …

[HTML][HTML] Diurnal variation of axial length, intraocular pressure, and anterior eye biometrics

SA Read, MJ Collins… - … ophthalmology & visual …, 2008 - iovs.arvojournals.org
purpose. To investigate the diurnal variation in axial length and anterior eye biometrics,
while simultaneously measuring intraocular pressure (IOP) with dynamic contour tonometry …