The state-of-the-art and emerging design approaches of double-tuned RF coils for X-nuclei, brain MR imaging and spectroscopy: A review
With the increasing availability of ultra-high field MRI systems, studying non-proton nuclei (X-
nuclei), such as 23 Na and 31 P has received great interest. X-nuclei are able to provide …
nuclei), such as 23 Na and 31 P has received great interest. X-nuclei are able to provide …
Broadband and multi-resonant sensors for NMR
It has always been of considerable interest to study the nuclear magnetic resonance
response of multiple nuclei simultaneously, whether these signals arise from internuclear …
response of multiple nuclei simultaneously, whether these signals arise from internuclear …
Automatic Tuning Matching Cycler (ATMC) in situ NMR spectroscopy as a novel approach for real-time investigations of Li-and Na-ion batteries
We have developed and explored the use of a new Automatic Tuning Matching Cycler
(ATMC) in situ NMR probe system to track the formation of intermediate phases and …
(ATMC) in situ NMR probe system to track the formation of intermediate phases and …
Design of standalone wireless impedance matching (SWIM) system for RF coils in MRI
SK Kandala, SM Sohn - Scientific reports, 2022 - nature.com
The radio frequency (RF) power transfer efficiency of transmit coils and the signal-to-noise
ratio (SNR) at the receive signal chain are directly dependent on the impedance matching …
ratio (SNR) at the receive signal chain are directly dependent on the impedance matching …
A generalized strategy for designing 19F/1H dual‐frequency MRI coil for small animal imaging at 4.7 Tesla
Purpose: To propose and test a universal strategy for building 19F/1H dual‐frequency RF
coil that permits multiple coil geometries. Materials and Methods: The feasibility to design …
coil that permits multiple coil geometries. Materials and Methods: The feasibility to design …
Design of an electrically automated RF transceiver head coil in MRI
SM Sohn, L DelaBarre, A Gopinath… - IEEE transactions on …, 2014 - ieeexplore.ieee.org
Magnetic resonance imaging (MRI) is a widely used nonionizing and noninvasive diagnostic
instrument to produce detailed images of the human body. The radio-frequency (RF) coil is …
instrument to produce detailed images of the human body. The radio-frequency (RF) coil is …
In vivo diffusion weighted 19F MRI using SF6
JM Pérez‐Sánchez, RP de Alejo… - … in Medicine: An …, 2005 - Wiley Online Library
Diffusion weighted 19F images of rat lung in vivo using SF6 are presented. Projection‐
reconstruction images were acquired by filling the rat lung with a mixture of SF6 and air …
reconstruction images were acquired by filling the rat lung with a mixture of SF6 and air …
[HTML][HTML] Optimization of saddle coils for magnetic resonance imaging
In Nuclear Magnetic Resonance (NMR) experiments, besides the apparatus designed to
acquire the NMR signal, it is necessary to generate a radio frequency electromagnetic field …
acquire the NMR signal, it is necessary to generate a radio frequency electromagnetic field …
Direct Method for the Determination of the Iodine Value of Biodiesel by Quantitative Nuclear Magnetic Resonance (q1H NMR) Spectroscopy
AS Sarpal, SR Silva, PRM Silva, TV Monteiro… - Energy & …, 2015 - ACS Publications
A direct, rapid, and convenient method for the determination of iodine value (IV) of
biodiesels from vegetable oils has been developed by the application of nuclear magnetic …
biodiesels from vegetable oils has been developed by the application of nuclear magnetic …
Imaging Capabilities of the ¹H-X-Nucleus Metamaterial-Inspired Multinuclear RF-Coil
V Puchnin, V Ivanov, M Gulyaev… - … on Medical Imaging, 2022 - ieeexplore.ieee.org
In this paper, we present the initial experimental investigation of a two-coil receive/transmit
design for small animals imaging at 7T MRI. The system uses a butterfly-type coil tuned to …
design for small animals imaging at 7T MRI. The system uses a butterfly-type coil tuned to …