Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities?
M Taylor, PJ Prendergast - Journal of biomechanics, 2015 - Elsevier
Finite element has been used for more than four decades to study and evaluate the
mechanical behaviour total joint replacements. In Huiskes seminal paper “Failed innovation …
mechanical behaviour total joint replacements. In Huiskes seminal paper “Failed innovation …
Numerical simulations on periprosthetic bone remodeling: a systematic review
AI Mirulla, S Pinelli, S Zaffagnini, V Nigrelli… - Computer Methods and …, 2021 - Elsevier
Background and objective The aim of the present study was to review the literature
concerning the analysis of periprosthetic bone remodeling through finite element (FE) …
concerning the analysis of periprosthetic bone remodeling through finite element (FE) …
Improving stress shielding following total hip arthroplasty by using a femoral stem made of β type Ti-33.6 Nb-4Sn with a Young's modulus gradation
G Yamako, D Janssen, S Hanada, T Anijs… - Journal of …, 2017 - Elsevier
Stress shielding-related bone loss occurs after total hip arthroplasty because the stiffness of
metallic implants differs from that of the host femur. Although reducing stem stiffness can …
metallic implants differs from that of the host femur. Although reducing stem stiffness can …
Novel adaptive finite element algorithms to predict bone ingrowth in additive manufactured porous implants
V San Cheong, P Fromme, A Mumith… - Journal of the …, 2018 - Elsevier
Bone loss caused by stress shielding of metallic implants is a concern, as it can potentially
lead to long-term implant failure. Surface coating and reducing structural stiffness of implants …
lead to long-term implant failure. Surface coating and reducing structural stiffness of implants …
On the optimal shape of hip implants
The success of a total hip arthroplasty is strongly related to the initial stability of the femoral
component and to the stress shielding effect. In fact, for cementless stems, initial stability is …
component and to the stress shielding effect. In fact, for cementless stems, initial stability is …
[HTML][HTML] A FE study on the effect of interference fit and coefficient of friction on the micromotions and interface gaps of a cementless PEEK femoral component
The use of a more compliant material, such as polyetheretherketone (PEEK), for a
cementless femoral component is a potential solution to prevent aseptic loosening caused …
cementless femoral component is a potential solution to prevent aseptic loosening caused …
Numerical analysis of an osseointegrated prosthesis fixation with reduced bone failure risk and periprosthetic bone loss
PK Tomaszewski, M Van Diest, SK Bulstra… - Journal of …, 2012 - Elsevier
Currently available implants for direct attachment of prosthesis to the skeletal system after
transfemoral amputation (OPRA system, Integrum AB, Sweden and ISP Endo/Exo …
transfemoral amputation (OPRA system, Integrum AB, Sweden and ISP Endo/Exo …
Simulated bone remodeling around two types of osseointegrated implants for direct fixation of upper-leg prostheses
PK Tomaszewski, N Verdonschot, SK Bulstra… - Journal of the …, 2012 - Elsevier
Direct attachment of an upper leg prosthesis to the skeletal system by a percutaneous
implant is an alternative solution to the traditional socket fixation. In this study, we …
implant is an alternative solution to the traditional socket fixation. In this study, we …
A comprehensive analysis of bio-inspired design of femoral stem on primary and secondary stabilities using mechanoregulatory algorithm
The coated porous section of stem surface is initially filled with callus that undergoes
osseointegration process, which develops a bond between stem and bone, lessens the …
osseointegration process, which develops a bond between stem and bone, lessens the …
Alternative designs of load− sharing cobalt chromium graded femoral stems
S Limmahakhun, A Oloyede, N Chantarapanich… - Materials Today …, 2017 - Elsevier
The incapability of controlling relative micromotions and load transfers to a peri-prosthetic
femur shortens implant longevity. This study aims to evaluate the possibility of applying …
femur shortens implant longevity. This study aims to evaluate the possibility of applying …