Posterior circulation flow diversion: a single-center experience and literature review

G Toth, M Bain, MS Hussain, S Moskowitz… - Journal of …, 2015 - jnis.bmj.com
Background Flow diverters have been used predominantly for large anterior circulation
aneurysms. Data on the safety and efficacy of this treatment for posterior circulation …

Cellular Level In-silico Modeling of Blood Rheology with An Improved Material Model for Red Blood Cells

G Závodszky, B Van Rooij, V Azizi… - Frontiers in physiology, 2017 - frontiersin.org
Many of the intriguing properties of blood originate from its cellular nature. Therefore,
accurate modeling of blood flow related phenomena requires a description of the dynamics …

Prediction of cerebral aneurysm hemodynamics with porous-medium models of flow-diverting stents via deep learning

G Li, X Song, H Wang, S Liu, J Ji, Y Guo, A Qiao… - Frontiers in …, 2021 - frontiersin.org
The interventional treatment of cerebral aneurysm requires hemodynamics to provide proper
guidance. Computational fluid dynamics (CFD) is gradually used in calculating cerebral …

An automatic CFD-based flow diverter optimization principle for patient-specific intracranial aneurysms

G Janiga, L Daróczy, P Berg, D Thévenin, M Skalej… - Journal of …, 2015 - Elsevier
The optimal treatment of intracranial aneurysms using flow diverting devices is a
fundamental issue for neuroradiologists as well as neurosurgeons. Due to highly irregular …

Initial experience with p64: a novel mechanically detachable flow diverter for the treatment of intracranial saccular sidewall aneurysms

S Fischer, M Aguilar-Pérez, E Henkes… - American Journal …, 2015 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Flow diverters are important tools for the treatment of
intracranial aneurysms. We report a retrospective evaluation of the safety and efficacy of …

Modeling and evaluation of biomechanics and hemodynamic based on patient-specific small intracranial aneurysm using fluid-structure interaction

Z Ma, Y Zhuang, X Long, B Yu, J Li, Y Yang… - Computer Methods and …, 2024 - Elsevier
Abstract Background and Objective Rupture of small intracranial aneurysm (IA) often leads
to the development of highly fatal clinical syndromes such as subarachnoid hemorrhage …

Selection of helical braided flow diverter stents based on hemodynamic performance and mechanical properties

T Suzuki, H Takao, S Fujimura, C Dahmani… - Journal of …, 2017 - jnis.bmj.com
Background Although flow diversion is a promising procedure for the treatment of
aneurysms, complications have been reported and it remains poorly understood. The …

Multiobjective design optimization of stent geometry with wall deformation for triangular and rectangular struts

NK Putra, PS Palar, H Anzai, K Shimoyama… - Medical & Biological …, 2019 - Springer
The stent geometrical design (eg, inter-strut gap, length, and strut cross-section) is
responsible for stent–vessel contact problems and changes in the blood flow. These …

Endothelial cell distributions and migration under conditions of flow shear stress around a stent wire

H Anzai, T Watanabe, X Han, NK Putra… - … and Health Care, 2020 - content.iospress.com
BACKGROUND: Blood vessels are constantly exposed to flow-induced stresses, and
endothelial cells (ECs) respond to these stresses in various ways. OBJECTIVE: In order to …

Early clinical experience with the new generation Pipeline Vantage flow diverter in the treatment of unruptured saccular aneurysms using short-term dual antiplatelet …

K Döring, A Aburub, JK Krauss… - Interventional …, 2023 - journals.sagepub.com
Purpose The Pipeline Vantage flow diverter with Shield technology (PV) used in this study is
a 4th-generation flow diverter (FD) designed to reduce thrombogenicity, promote …