Control algorithms of shunt active power filter for harmonics mitigation: A review

Y Hoon, MA Mohd Radzi, MK Hassan, NF Mailah - Energies, 2017 - mdpi.com
Current harmonics is one of the most significant power quality issues which has attracted
tremendous research interest. Shunt active power filter (SAPF) is the best solution to …

Shunt active power filter: A review on phase synchronization control techniques

Y Hoon, MA Mohd Radzi, MAA Mohd Zainuri… - Electronics, 2019 - mdpi.com
Owing to the destructive impacts of harmonic currents, the topic of reducing their impacts on
power system has attracted tremendous research interests. In this regard, a shunt active …

Topological aspects of power quality improvement techniques: A comprehensive overview

OP Mahela, AG Shaik - Renewable and Sustainable Energy Reviews, 2016 - Elsevier
Recently utilities are continuously seeking cost-effective and accurate power quality (PQ)
improvement techniques in order to achieve customer satisfaction. This paper intends to …

Power quality and stability improvement of microgrid through shunt active filter control application: An overview

B Sahoo, MM Alhaider, PK Rout - Renewable Energy Focus, 2023 - Elsevier
Owing to avoid harmonic and power quality issues, the concept of eliminating their impacts
on microgrid systems has gained a lot of interest. Incidentally, shunt active filters (SHAFs) is …

TS-fuzzy-controlled active power filter for load compensation

CN Bhende, S Mishra, SK Jain - IEEE transactions on power …, 2006 - ieeexplore.ieee.org
This paper describes the application of Takagi-Sugeno (TS)-type fuzzy logic controller to a
three-phase shunt active power filter for the power-quality improvement and reactive power …

Bacterial foraging technique-based optimized active power filter for load compensation

S Mishra, CN Bhende - IEEE transactions on power delivery, 2006 - ieeexplore.ieee.org
The conventional method of obtaining the coefficients of proportional plus integral (PI)
controllers for the active power filter utilizes a linear model of the PWM inverter. The values …

PI and fuzzy logic controllers for shunt active power filter—A report

P Karuppanan, KK Mahapatra - ISA transactions, 2012 - Elsevier
This paper presents a shunt Active Power Filter (APF) for power quality improvements in
terms of harmonics and reactive power compensation in the distribution network. The …

Fuzzy particle swarm optimization control algorithm implementation in photovoltaic integrated shunt active power filter for power quality improvement using hardware …

R Kumar - Sustainable Energy Technologies and Assessments, 2022 - Elsevier
This paper proposes a hybrid fuzzy particle swarm optimization (FPSO) technique with a
photovoltaic fed shunt active power filter (SAPF) to improve power quality and deliver clean …

Fuzzy logic controller for three-level shunt active filter compensating harmonics and reactive power

S Saad, L Zellouma - Electric Power Systems Research, 2009 - Elsevier
In this paper, the three-level inverter is used as a shunt active power filter, making use of the
multilevel inverter advantages of low harmonic distortion, and reduced switching losses …

Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction

Y Hoon, MAM Radzi, MK Hassan… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
In this paper, a new reference current generation method is proposed for effective harmonics
mitigation and reactive power compensation of three-level neutral-point diode clamped …