The Thick Gas Electron Multiplier and its derivatives: Physics, technologies and applications

S Bressler, L Moleri, A Jash, A Tesi… - Progress in particle and …, 2023 - Elsevier
Abstract The Thick Gas Electron Multiplier (THGEM) is a robust high-gain gas-avalanche
electron multiplier–a building block of a variety of radiation detectors. It can be manufactured …

Review of liquid argon detector technologies in the neutrino sector

K Majumdar, K Mavrokoridis - Applied Sciences, 2021 - mdpi.com
Liquid Argon (LAr) is one of the most widely used scintillators in particle detection, due to its
low cost, high availability and excellent scintillation properties. A large number of …

Neutral bremsstrahlung emission in xenon unveiled

CAO Henriques, P Amedo, JMR Teixeira… - Physical Review X, 2022 - APS
We present evidence of non-excimer-based secondary scintillation in gaseous xenon,
obtained using both the NEXT-White time projection chamber (TPC) and a dedicated setup …

Electroluminescence and electron avalanching in two-phase detectors

A Buzulutskov - Instruments, 2020 - mdpi.com
Electroluminescence and electron avalanching are the physical effects used in two-phase
argon and xenon detectors for dark matter searches and neutrino detection, to amplify the …

[HTML][HTML] Performance of the ReD TPC, a novel double-phase LAr detector with silicon photomultiplier readout

P Agnes, S Albergo, I Albuquerque, M Arba… - The European Physical …, 2021 - Springer
A double-phase argon Time Projection Chamber (TPC), with an active mass of 185 g, has
been designed and constructed for the Recoil Directionality (ReD) experiment. The aim of …

Neutral bremsstrahlung electroluminescence in noble liquids

E Borisova, A Buzulutskov - Europhysics Letters, 2022 - iopscience.iop.org
Proportional electroluminescence (EL) is the physical effect used in two-phase dark matter
detectors, to optically record in the gas phase the ionization signal produced by particle …

Neutral bremsstrahlung and excimer electroluminescence in noble gases and its relevance to two-phase dark matter detectors

E Borisova, A Buzulutskov - The European Physical Journal C, 2021 - Springer
Proportional electroluminescence (EL) is the physical effect used in two-phase detectors for
dark matter searches, to optically record (in the gas phase) the ionization signal produced by …

Neutral bremsstrahlung in TPCs

P Amedo, D González-Díaz… - Journal of …, 2022 - iopscience.iop.org
Traditionally, it has been assumed that electroluminescence (EL) in time projection
chambers was purely an excimer-based emission. This idea changed when neutral …

Characterization of two SiPM arrays from Hamamatsu and Onsemi for liquid argon detector

TA Wang, C Guo, XH Liang, L Wang, MY Guan… - Nuclear Instruments and …, 2023 - Elsevier
Silicon photomultiplier is considered a substitute for traditional photomultiplier tube in the
next generation of dark matter and neutrino detectors, especially in noble gas detectors like …

[HTML][HTML] Puzzling time properties of proportional electroluminescence in two-phase argon detectors for dark matter searches

A Buzulutskov, E Frolov, E Borisova, V Nosov… - The European Physical …, 2022 - Springer
Proportional electroluminescence (EL) in noble gases is a physical process routinely used
in two-phase (liquid–gas) detectors for low-energy astroparticle-physics experiments. In this …