Biomechanical property and modelling of venous wall
W Li - Progress in biophysics and molecular biology, 2018 - Elsevier
Human saphenous vein has long been used as coronary artery bypass grafts to survive a
heart arrested by blocked coronary arteries. Biomechanical properties of the saphenous …
heart arrested by blocked coronary arteries. Biomechanical properties of the saphenous …
Toward a physiological model of vascular wall vibrations in the arteriovenous fistula
L Soliveri, D Bruneau, J Ring, M Bozzetto… - … and Modeling in …, 2024 - Springer
The mechanism behind hemodialysis arteriovenous fistula (AVF) failure remains poorly
understood, despite previous efforts to correlate altered hemodynamics with vascular …
understood, despite previous efforts to correlate altered hemodynamics with vascular …
A comparative analysis of coronary bypass implants: Experimental and fluid-structure interaction analysis
S Changizi, N Afrasiabian, A Rassoli… - Biocybernetics and …, 2024 - Elsevier
Bypass surgery is a commonly employed method for treating coronary artery diseases,
involving the use of grafts to bypass occluded arteries. However, graft occlusion remains a …
involving the use of grafts to bypass occluded arteries. However, graft occlusion remains a …
A comparative study of storage solutions on the biomechanical preservation of human saphenous veins
Y Wei, Y Zhou, C Weng, D Yuan, T Zheng - Journal of Biomechanics, 2025 - Elsevier
Storage solutions have a significant impact on the physiological properties of saphenous
veins (SV), yet their effects on the biomechanics remained unclear. This study investigated …
veins (SV), yet their effects on the biomechanics remained unclear. This study investigated …
Haemodynamic impact of implant materials and anastomotic angle in peripheral vascular grafts
S Schoenborn, T Lloyd, Y Sivakumaran, MA Woodruff… - bioRxiv, 2024 - biorxiv.org
End-to-side anastomoses are commonly utilised in peripheral arterial bypass surgery and
are plagued by high rates of re-stenosis as a result of non-physiological blood flow …
are plagued by high rates of re-stenosis as a result of non-physiological blood flow …
Comparison of the mechanical properties of bypass grafts: Experimental assays
Objective One prevalent therapeutic strategy for addressing atherosclerosis is using an
alternative blood supply route to the heart, referred to as bypass surgery. In these surgeries …
alternative blood supply route to the heart, referred to as bypass surgery. In these surgeries …
High-frequency wall vibrations in arteriovenous fistula: unveiling a novel mechanobiological stimulus for adverse vascular remodeling
L Soliveri - 2024 - politesi.polimi.it
Despite advancements in clinical, computational, and experimental research, the
mechanobiological mechanisms underlying adverse vascular remodeling and failure in …
mechanobiological mechanisms underlying adverse vascular remodeling and failure in …
[引用][C] Fluid-Structure Interactions in Peripheral Arteries: Biomechanical Coupling of In-Silico, In-Vitro, and Cellular Models with Application to Patient-Specific Femoral …
S Schoenborn - 2024 - espace.library.uq.edu.au
The primary cause of mid-term occlusive graft failure in small-diameter vascular bypass
grafts is the development of intimal hyperplasia, the abnormal thickening of the tunica intima …
grafts is the development of intimal hyperplasia, the abnormal thickening of the tunica intima …