Prompt-gamma monitoring in hadrontherapy: A review

J Krimmer, D Dauvergne, JM Létang, É Testa - Nuclear Instruments and …, 2018 - Elsevier
Secondary radiation emission induced by nuclear reactions is correlated to the path of ions
in matter. Therefore, such penetrating radiation can be used for in vivo control of …

In vivo proton range verification: a review

AC Knopf, A Lomax - Physics in Medicine & Biology, 2013 - iopscience.iop.org
Protons are an interesting modality for radiotherapy because of their well defined range and
favourable depth dose characteristics. On the other hand, these same characteristics lead to …

In vivo range verification in particle therapy

K Parodi, JC Polf - Medical physics, 2018 - Wiley Online Library
Exploitation of the full potential offered by ion beams in clinical practice is still hampered by
several sources of treatment uncertainties, particularly related to the limitations of our ability …

[HTML][HTML] The FLUKA code: an accurate simulation tool for particle therapy

G Battistoni, J Bauer, TT Boehlen, F Cerutti… - Frontiers in …, 2016 - frontiersin.org
Monte Carlo (MC) codes are increasingly spreading in the hadrontherapy community due to
their detailed description of radiation transport and interaction with matter. The suitability of a …

Prompt gamma imaging with a slit camera for real-time range control in proton therapy

J Smeets, F Roellinghoff, D Prieels… - Physics in Medicine …, 2012 - iopscience.iop.org
Treatments delivered by proton therapy are affected by uncertainties on the range of the
beam within the patient, requiring medical physicists to add safety margins on the …

[HTML][HTML] Range verification methods in particle therapy: underlying physics and Monte Carlo modeling

AC Kraan - Frontiers in oncology, 2015 - frontiersin.org
Hadron therapy allows for highly conformal dose distributions and better sparing of organs-
at-risk, thanks to the characteristic dose deposition as function of depth. However, the quality …

Range assessment in particle therapy based on prompt γ-ray timing measurements

C Golnik, F Hueso-González, A Müller… - Physics in Medicine …, 2014 - iopscience.iop.org
Proton and ion beams open up new vistas for the curative treatment of tumors, but adequate
technologies for monitoring the compliance of dose delivery with treatment plans in real time …

3D prompt gamma imaging for proton beam range verification

E Draeger, D Mackin, S Peterson, H Chen… - Physics in Medicine …, 2018 - iopscience.iop.org
We tested the ability of a single Compton camera (CC) to produce 3-dimensional (3D)
images of prompt gammas (PGs) emitted during the irradiation of a tissue-equivalent plastic …

Prompt gamma imaging of proton pencil beams at clinical dose rate

I Perali, A Celani, L Bombelli, C Fiorini… - Physics in Medicine …, 2014 - iopscience.iop.org
In this work, we present experimental results of a prompt gamma camera for real-time proton
beam range verification. The detection system features a pixelated Cerium doped lutetium …

Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy

M Moteabbed, S Espana… - Physics in Medicine & …, 2011 - iopscience.iop.org
The purpose of this work was to compare the clinical adaptation of prompt gamma (PG)
imaging and positron emission tomography (PET) as independent tools for non-invasive …