A robust single ended disturbance detection scheme for superconducting fault current limiter integrated UPFC compensated line

A Panday, MT Ahmad, S Biswal, RD Patidar… - Electric Power Systems …, 2023 - Elsevier
The occurrence of short circuit events in a high voltage or extra high voltage transmission
system may result in a fault current with high magnitudes. Additionally, the inclusion of …

Time-Domain Based Distance Protection for Transmission Networks: Secure and Reliable Solution for Complex Networks

OD Naidu, N George, S Zubic, M Krakowski - IEEE Access, 2023 - ieeexplore.ieee.org
Distance protection is popular in transmission networks and constitutes a large installed
base across grid systems. The most widely accepted implementation of distance protection …

Estimation of polarity of slope of instantaneous current increment for power swing immune protection of series compensated line

B Patel - Measurement, 2025 - Elsevier
Existing protection schemes for series-compensated transmission line (SCTL) lack either in
reliability or speed during power swing (PS). A new ultra-fast reliable method is proposed in …

Improving protection reliability of series‐compensated transmission lines by a fault detection method through an ML‐based model

H Ebrahimi, S Golshannavaz… - IET Generation …, 2024 - Wiley Online Library
This article addresses the distance protection challenges associated with the series‐
compensated transmission lines and the impact of fault resistance by employing a machine …

A differential amplitude variation based pilot relaying scheme for microgrid integrated distribution system

B Deshmukh, DK Lal, S Biswal… - International Journal of …, 2024 - degruyter.com
The inclusion of inverter-interfaced distributed generating sources (IIDGS) in the active
distribution network offers operational and protection constraints. Dynamic fault behavior of …

Performance of Memory-Polarized Distance Relay in Presence of PV Generator with Control

A Radhakrishnan, A Ghosh… - 2022 IEEE Energy …, 2022 - ieeexplore.ieee.org
This paper presents novel results associated with the impact of PV generator controls on the
distance protection. Memory voltage polarization of mho element leads to dynamic …

An improved strategy for out-of-step oscillation separation devices based on apparent impedance angle applied to a series compensated line

H Xu, Y Cai, X Qu, Z Dong - Protection and Control of Modern …, 2022 - ieeexplore.ieee.org
Out-of-step oscillation separation devices based on apparent impedance angle trajectory
are widely used in the power grid in China, and their reliability is of great importance. In this …

New time domain distance protection for renewable connected and series compensated transmission lines

OD Naidu, M Krakowski, S Zubic - 2024 - IET
The nature of today's power transmission networks is getting more complicated and
dynamic. Fast, secure, and dependable protection decisions are required for systems that …

Protection of Series Compensated Networks Using Different Techniques: An Overview

SU Kakaiya, RP Mehta - … Conference on Power Engineering and Intelligent …, 2024 - Springer
The emerging demand for electricity has made power systems flexible and wider. This
increasing demand for electricity can be met by increasing the power transfer capability of …

Time Domain Distance Protection for Series Compensated Transmission Lines Using RC and RLC Line Models

MT Hoq, J Wang, N Taylor - Available at SSRN 4462848, 2023 - papers.ssrn.com
Fast time-domain distance protection using RL and RLC models of a trans-mission line is
presented in this paper for application to series compensatedtransmission lines. The …