A detailed investigation of HPGe detector response for improved Monte Carlo efficiency calculations
J Boson, G Ågren, L Johansson - … and Methods in Physics Research Section …, 2008 - Elsevier
Monte Carlo simulations using MCNP5 software have been performed in order to estimate
the full-energy-peak efficiency of an HPGe detector. Since a discrepancy was found …
the full-energy-peak efficiency of an HPGe detector. Since a discrepancy was found …
Experimental and simulated efficiency of a HPGe detector with point-like and extended sources
D Karamanis, V Lacoste, S Andriamonje… - Nuclear Instruments and …, 2002 - Elsevier
The absolute efficiency of a high purity germanium (HPGe) detector was determined with a
point-like calibrated 152Eu source at two distances from the detector and three pure metallic …
point-like calibrated 152Eu source at two distances from the detector and three pure metallic …
Monte Carlo efficiency transfer method for full energy peak efficiency calibration of three type HPGe detectors: a coaxial N-type, a coaxial P-type and four BEGe …
L Liye, M Jizeng, D Franck, L de Carlan… - Nuclear Instruments and …, 2006 - Elsevier
Monte Carlo efficiency transfer method was used to determine full energy peak efficiency of
three type high-purity germanium (HPGe) detectors: a coaxial N-type, a coaxial P-type and …
three type high-purity germanium (HPGe) detectors: a coaxial N-type, a coaxial P-type and …
Parameter optimization of a planar BEGe detector using Monte Carlo simulations
R Luís, J Bento, G Carvalhal, P Nogueira, L Silva… - Nuclear Instruments and …, 2010 - Elsevier
This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX,
PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) …
PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) …
Monte Carlo based geometrical model for efficiency calculation of an n-type HPGe detector
FP Cabal, N Lopez-Pino, JL Bernal-Castillo… - Applied Radiation and …, 2010 - Elsevier
A procedure to optimize the geometrical model of an n-type detector is described. Sixteen
lines from seven point sources (241Am, 133Ba, 22Na, 60Co, 57Co, 137Cs and 152Eu) …
lines from seven point sources (241Am, 133Ba, 22Na, 60Co, 57Co, 137Cs and 152Eu) …
Accounting for incomplete charge collection in Monte Carlo simulations of the efficiency of well-type Ge-detectors
F Hernández, F El-Daoushy - Nuclear Instruments and Methods in Physics …, 2003 - Elsevier
The influence of the process of incomplete charge collection on the performance properties
of HPGe well-type detectors is studied. A simplified sub-routine, that takes into account the …
of HPGe well-type detectors is studied. A simplified sub-routine, that takes into account the …
A semi-empirical model of the efficiency curve for extended sources in gamma-ray spectrometry
T Vidmar, M Korun, A Likar, R Martinčič - Nuclear Instruments and Methods …, 2001 - Elsevier
A semi-empirical formula for the full energy peak efficiency of extended sources in the range
from 4 to 3000 keV is presented, taking into account self-absorption in the sample. The …
from 4 to 3000 keV is presented, taking into account self-absorption in the sample. The …
Monte-Carlo modeling of a NaI (Tl) scintillator
S Ashrafi, S Anvarian, S Sobhanian - Journal of radioanalytical and …, 2006 - akjournals.com
A NaI (Tl) scintillator detector has been modeled using GEANT simulation tool. Uniformity of
the light collection efficiency was investigated by allowing a narrowly collimated beam of …
the light collection efficiency was investigated by allowing a narrowly collimated beam of …
Verification of 235U mass content in nuclear fuel plates by an absolute method
W El-Gammal - Nuclear Instruments and Methods in Physics Research …, 2007 - Elsevier
Nuclear Safeguards is referred to a verification System by which a State can control all
nuclear materials (NM) and nuclear activities under its authority. An effective and efficient …
nuclear materials (NM) and nuclear activities under its authority. An effective and efficient …
Automated construction of detector models for efficiency interpolation in gamma-ray spectrometry
T Vidmar, A Likar - Applied Radiation and Isotopes, 2002 - Elsevier
A method was developed for automated construction of detector models in gamma-ray
spectrometry, which can be used in Monte Carlo calculations of efficiency calibration curves …
spectrometry, which can be used in Monte Carlo calculations of efficiency calibration curves …