Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions

D Buser, L Sennerby, H De Bruyn - Periodontology 2000, 2017 - Wiley Online Library
In the 1960s and 1970s, implant‐supported prostheses based on subperiosteal or blade
implants had a poor reputation because of questionable clinical outcomes and lack of …

Multi-scale surface treatments of titanium implants for rapid osseointegration: a review

Q Wang, P Zhou, S Liu, S Attarilar, RLW Ma, Y Zhong… - Nanomaterials, 2020 - mdpi.com
The propose of this review was to summarize the advances in multi-scale surface
technology of titanium implants to accelerate the osseointegration process. The several multi …

Direct and indirect effects of microstructured titanium substrates on the induction of mesenchymal stem cell differentiation towards the osteoblast lineage

R Olivares-Navarrete, SL Hyzy, DL Hutton, CP Erdman… - Biomaterials, 2010 - Elsevier
Microstructured and high surface energy titanium substrates increase osseointegration in
vivo. In vitro, osteoblast differentiation is increased, but effects of the surface directly on …

Does length, diameter, or bone quality affect primary and secondary stability in self-tapping dental implants?

M Gomez-Polo, R Ortega, C Gomez-Polo… - Journal of Oral and …, 2016 - Elsevier
Purpose Implant stability is a clinically valuable measurement of the strength of implant
anchorage in the bone during placement and in the post-osseointegration period. This study …

Current knowledge about the hydrophilic and nanostructured SLActive surface

A Wennerberg, S Galli, T Albrektsson - Clinical, cosmetic and …, 2011 - Taylor & Francis
This review summarizes the present documentation for the SLActive surface, a hydrophilic
and nanostructured surface produced by Straumann Company in Switzerland, and covers …

Efficacy of standard (SLA) and modified sandblasted and acid‐etched (SLA ctive) dental implants in promoting immediate and/or early occlusal loading protocols: a …

L Chambrone, JA Shibli, CE Mercúrio… - Clinical Oral …, 2015 - Wiley Online Library
Objective To assess the survival percentage, clinical and radiographic outcomes of
sandblasted and acid‐etched (SLA) dental implants and its modified surface (SLA ctive) in …

Primary stability optimization by using fixtures with different thread depth according to bone density: a clinical prospective study on early loaded implants

C Makary, A Menhall, C Zammarie, T Lombardi, SY Lee… - Materials, 2019 - mdpi.com
Background: Macro-and micro-geometry are among the factors influencing implant stability
and potentially determining loading protocol. The purpose of this study was to test a protocol …

Surface modification of metallic biomaterials for better tribological properties: A review

ZA Uwais, MA Hussein, MA Samad… - Arabian Journal for …, 2017 - Springer
Biomaterials are extensively used in the medical field for biological tissue replacement and
internal support, such as joint replacement, dental roots, and orthopedic implants. The …

Mechanical, chemical and laser treatments of the implant surface in the presence of marginal bone loss around implants.

J Meyle - European journal of oral implantology, 2012 - search.ebscohost.com
Purpose: The objective of this review was to summarise current evidence with regard to the
decontamination of implant surfaces by mechanical, chemical and physical methods in the …

Early loading at 21 days of non‐submerged titanium implants with a chemically modified sandblasted and acid‐etched surface: 3‐year results of a prospective study in …

MM Bornstein, JG Wittneben, U Brägger… - Journal of …, 2010 - Wiley Online Library
Background: This study evaluates 3‐year success rates of titanium screw‐type implants with
a chemically modified sandblasted and acid‐etched surface (mod SLA), which were …